Titanium miniplates or stainless steel wire for cranial fixation: a prospective randomized comparison

Author:

Broaddus William C.,Holloway Kathryn L.,Winters Charles J.,Bullock M. Ross,Graham R. Scott,Mathern Bruce E.,Ward John D.,Young Harold F.

Abstract

Object. The authors designed a study to compare low-profile titanium miniplate fixation to that in which stainless steel wire is used. Methods. Before undergoing craniotomy, 40 patients gave informed consent and were randomized to receive either wire or miniplate fixation. After dural closure, bone flap fixation was timed. The bone flap was measured for inward or outward offset and mobility to manual pressure on its margin. Three months postoperatively the bone flap margins were graded for appearance or palpation of an offset and for the presence of burr hole depressions. Twenty-four patients were randomized to receive miniplate fixation and 16 to receive stainless steel wire fixation. The time required for wire fixation was approximately 40% longer than that for miniplates (11.8 ± 5.1 minutes compared with 8.3 ± 5 minutes, p = 0.02). The offset of bone flaps after wire fixation was significantly greater than that with miniplates (1.6 ± 1 mm compared with 0.3 ± 0.6 mm, p < 0.001), as was the mobility of the bone flap on digital pressure (1.2 ± 0.9 mm compared with 0.2 ± 0.5 mm, p < 0.001). At the 3-month follow-up review, two of 12 patients had suboptimal results after wire fixation, whereas none of 14 patients had suboptimal results after miniplate fixation. When dichotomized for excellent or less-than-excellent postoperative results, the data were significantly better for patients who underwent miniplate fixation (p < 0.05). Conclusions. Titanium miniplate cranial fixation provides more accurate and rigid reapproximation of the bone edges, with results that are significantly better on close inspection or palpation. The additional cost of miniplate fixation may thus be justified in many cases.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Surface Modifications of Medical Grade Stainless Steel;Coatings;2024-02-20

2. Advanced silk materials for musculoskeletal tissue regeneration;Frontiers in Bioengineering and Biotechnology;2023-05-02

3. Electrodeposition of hydroxyapatite and graphene oxide improves the bioactivity of medical grade stainless steel;Materials Today Sustainability;2022-11

4. Optimizing cranial implant and fixture design using different materials in cranioplasty;Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications;2022-05-31

5. Intraoperative extracorporeal irradiation for giant sarcoma-infiltrated calvarium: a case report;British Journal of Neurosurgery;2021-02-28

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3