Are ultrasonography measurements of optic nerve sheath diameter an alternative to funduscopy in children with syndromic craniosynostosis?

Author:

Driessen Caroline1,Bannink Natalja1,Lequin Maarten2,van Veelen Marie-Lise C.3,Naus Nicole C.4,Joosten Koen F. M.5,Mathijssen Irene M. J.1

Affiliation:

1. Departments of Plastic and Reconstructive Surgery,

2. Radiology,

3. Neurosurgery,

4. Ophthalmology, and

5. Pediatrics, Dutch Craniofacial Centre, Erasmus MC Sophia Children's Hospital, Rotterdam, The Netherlands

Abstract

Object Children with syndromic or complex craniosynostosis are evaluated for increased intracranial pressure (ICP) using funduscopy to detect papilledema. However, papilledema is a late sign of increased ICP. Because papilledema might be preceded by an increase in optic nerve sheath (ONS) diameter, the authors conducted a prospective study to establish the validity and applicability of measuring the ONS using ultrasonography. Methods From January 2007 to December 2009, 175 bilateral ultrasonography ONS measurements were performed in 128 patients with syndromic or complex craniosynostosis during the daytime. The measurements were correlated with ONS diameter assessed on CT and simultaneous funduscopy, when available. Furthermore, results were compared by using thresholds for ONS diameters on ultrasonography that are available in the literature. Results The mean ONS diameter on ultrasonography was 3.1 ± 0.5 mm. The CT measurement was significantly correlated with the ultrasonography measurement (r = 0.41, p < 0.001). The mean ONS diameter in 38 eyes with papilledema was 3.3 ± 0.5 mm, compared with 3.1 ± 0.5 mm in the eyes of patients without papilledema (p = 0.039). Relative to the age-related thresholds, the ONS diameter was too large in 11 eyes (3%), particularly in patients with Crouzon syndrome. Compared with funduscopy, ultrasonography sensitivity was 11%, specificity was 97%, and positive and negative predictive values were 40% and 86%, respectively. Conclusions Ultrasonography is a valid and easy way of quantifying the ONS. Although the ONS diameter is larger in children with papilledema, it cannot be used as a daytime screening tool instead of funduscopy. The ONS diameter is possibly a more real-time indicator of ICP.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3