Learning brain aneurysm microsurgical skills in a human placenta model: predictive validity

Author:

de Oliveira Marcelo Magaldi Ribeiro12,Ferrarez Carlos Eduardo1,Ramos Taise Mosso1,Malheiros Jose Augusto1,Nicolato Arthur1,Machado Carla Jorge3,Ferreira Mauro Tostes1,de Oliveira Fellype Borges1,de Sousa Cecília Félix Penido Mendes1,Costa Pollyana Helena Vieira1,Gusmao Sebastiao1,Lanzino Giuseppe4,Maestro Rolando Del2

Affiliation:

1. Microsurgical Laboratory, Medical School, and

2. Neurosurgical Simulation Research and Training Centre, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada; and

3. Department of Preventive and Social Medicine, Federal University of Minas Gerais, Belo Horizonte, Brazil;

4. Department of Neurological Surgery, Mayo Clinic, Rochester, Minnesota

Abstract

OBJECTIVESurgery for brain aneurysms is technically demanding. In recent years, the process to learn the technical skills necessary for these challenging procedures has been affected by a decrease in the number of surgical cases available and progressive restrictions on resident training hours. To overcome these limitations, surgical simulators such as cadaver heads and human placenta models have been developed. However, the effectiveness of these models in improving technical skills is unknown. This study assessed concurrent and predictive validity of brain aneurysm surgery simulation in a human placenta model compared with a “live” human brain cadaveric model.METHODSTwo human cadaver heads and 30 human placentas were used. Twelve neurosurgeons participated in the concurrent validity part of this study, each operating on 1 human cadaver head aneurysm model and 1 human placenta model. Simulators were evaluated regarding their ability to simulate different surgical steps encountered during real surgery. The time to complete the entire aneurysm task in each simulator was analyzed. The predictive validity component of the study involved 9 neurosurgical residents divided into 3 groups to perform simulation exercises, each lasting 6 weeks. The training for the 3 groups consisted of educational video only (3 residents), human cadaver only (3 residents), and human placenta only (3 residents). All residents had equivalent microsurgical experience with superficial brain tumor surgery. After completing their practice training, residents in each of the 3 simulation groups performed surgery for an unruptured middle cerebral artery (MCA) aneurysm, and their performance was assessed by an experienced vascular neurosurgeon who watched the operative videos.RESULTSAll human cadaver heads and human placentas were suitable to simulate brain aneurysm surgery. In the concurrent validity portion of the experiment, the placenta model required a longer time (p < 0.001) than cadavers to complete the task. The placenta model was considered more effective than the cadaver model in simulating sylvian fissure splitting, bipolar coagulation of oozing microvessels, and aneurysm neck and dome dissection. Both models were equally effective in simulating neck aneurysm clipping, while the cadaver model was considered superior for simulation of intraoperative rupture and for reproduction of real anatomy during simulation. In the predictive validity portion of the experiment, residents were evaluated for 4 tasks: sylvian fissure dissection, microvessel bipolar coagulation, aneurysm dissection, and aneurysm clipping. Residents trained in the human placenta simulator consistently had the highest overall performance scores when compared with those who had trained in the cadaver model and those who had simply watched operative videos (p < 0.001).CONCLUSIONSThe human placenta biological simulator provides excellent simulation for some critical tasks of aneurysm surgery such as splitting of the sylvian fissure, dissection of the aneurysm neck and dome, and bipolar coagulation of surrounding microvessels. When performing surgery for an unruptured MCA aneurysm, residents who had trained in the human placenta model performed better than residents trained with other simulation scenarios/models. In this age of reduced exposure to aneurysm surgery and restrictions on resident working hours, the placenta model is a valid simulation for microneurosurgery with striking similarities with real surgery.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Reference50 articles.

1. New laboratory model for neurosurgical training that simulates live surgery;Aboud;J Neurosurg,2002

2. Microvascular anastomosis training model based on a turkey neck with perfused arteries;ColpanME;Neurosurgery,2008

3. Human placenta as an ex vivo vascular model for neurointerventional research;Kwok;J Neurointerv Surg,2014

4. The use of placenta in a microvascular exercise;Ayoubi;Neurosurgery,1992

5. Microsurgical cerebral aneurysm training porcine model;Olabe;Neurol India,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3