Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients

Author:

Amato Vincenzo,Giannachi Luigi,Irace Claudio,Corona Claudio

Abstract

ObjectThe goal of this study was to determine the incidence of screw misplacement and complications in a group of 102 patients who underwent transpedicle screw fixation in the lumbosacral spine with conventional open technique and intraoperative fluoroscopy. The results are compared with published data.MethodsCases involving 102 consecutive patients (424 inserted screws) were reviewed. Surgery was performed in all cases by the same surgeon's team, using the same implant, and all results were assessed by means of a specific CT protocol. The screw position was assessed by the authors and an independent observer. Screw position was classified as correct when the screw was completely surrounded by the pedicle cortex, as “cortical encroachment” (questionable violation) if the pedicle cortex could not be visualized, and as “frank penetration” when the screw was outside the pedicular boundaries. Frank penetration was further subdivided as minor (when the edge of the screw thread was up to 2.0 mm outside the pedicle cortex), moderate (2.1–4 mm), and severe (> 4 mm). The incidence of intra- and postoperative complications not related to screw position as well as hardware failures were also registered, with a minimum follow-up duration of 8 months.ResultsThe rate of frank pedicle screw misplacement was 5%. The rate of minimal or questionable pedicle wall violation was 2.8%. Among the frank misplacements, 6 were classified as minor, 12 as moderate, and 3 as severe penetration. Two patients (2%) had radicular pain and neurological deficits (inferomedial and inferolateral minor misplacement at L-4 and L-5, respectively), and 5 patients (4.9%) complained only of radicular pain. At the follow-up examination all patients had completely recovered their neurological function and radicular pain was resolved in all cases. The complications not related to screw malposition were 2 pedicle fractures (2% of patients), 1 nerve root injury (1%), and 1 dural laceration (1%). Five patients (4.8%) had postoperative anemia and required transfusions. Superficial or deep wound infection was noted in 3 patients (2.9%). Late hardware failure occurred in 2 patients (2%). One patient developed adjacent segmental instability and required additional surgery to extend the fusion.ConclusionsOur rates of screw misplacement and complications compare favorably with the lowest rates of the series in which conventional technique was used and are close to the rates reported for image-guided methods. The risk of malpositioning may be reduced with careful preoperative surgical planning, accurate knowledge of the spinal anatomy, surgical experience, and correct indication for conventional surgery. The conventional technique still remains a practical, safe, and effective surgical method for lumbosacral fixation.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 106 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3