An anterior cervical retractor utilizing a novel principle

Author:

Seex Kevin A.

Abstract

The alarmingly high soft-tissue complication rates after anterior cervical surgery suggests that the design of current retractors is inadequate. A review of retractor design and consideration of new designs is worthwhile. The author reviewed the literature and the 7 described devices (Cloward, Caspar, Thompson-Farley, Tresserras, Ozer, Takayasu, and Oh devices). With the exception of Cloward/Caspar and Thomson-Farley systems, the author's search of the literature failed to disclose any independent review or investigations of the other retractors, suggesting that the use of these devices is limited. The Cloward/Caspar-style retractors depend for stability on small teeth at the ends of the blades that impale and stretch the longus colli muscle. For stability this self-retaining design requires equal tissue counterpressure. These devices are thus ill suited for a wound with substantially greater pressure from the medial structures and are prone to migration. The Thomson-Farley type of systems use arms with mechanical joints fixed to a table-mounted frame. The releasable joints allow adjustability and independent relaxation. Their limitations include bulk causing obstruction to the surgeons and radiographs, increased setup time, and ease with which excessive force can be applied. The author describes a new anterior cervical retractor that is based on a novel principle. The principle is that bone fixation can be used to provide the retractor blade an axis of rotation inside the wound. This gives improved retractor blade stability with the mechanical advantage of a lever. The stable rotation produced allows adjustable retraction and tissue relaxation without compromise in stability. To the author's knowledge, there are no previously described retractors with this ability. The system consists of a small 2-piece sliding frame fixed to the spine with the distraction screws. Bone fixation is preferable to sharp teeth and longus colli dissection because it works better and heals without scarring. Surgery is carried out through the frame, which slides during distraction. Independent retractor blades are attached to the sides of the frame, which provides a stable craniocaudal axis inside the wound. The blades rotate to provide retraction or relaxation as required. Intermittent relaxation of tissues under retractors has been shown to be beneficial. Another advantage, compared with systems that maintain wounds with vertical sides, is the ease with which an oblique approach can be used. The mechanical advantage has 3 benefits. First, bulky external mechanisms for retraction are avoided, which improves access. Second, numerous blade lengths are unnecessary, reducing inventory. Third, radiolucent polymers can be used with “snap-fit” properties. The improved stability over conventional systems reduces the need for skilled assistance and avoids surgeon frustration after retraction migration. Over a 3-year period, 100 anterior cervical operations have been performed. Anecdotally, operations are quicker mainly because the retractors do not slip. Prospective clinical studies with independent evaluation are underway.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3