Two-level total disc replacement with Mobi-C cervical artificial disc versus anterior discectomy and fusion: a prospective, randomized, controlled multicenter clinical trial with 4-year follow-up results

Author:

Davis Reginald J.1,Nunley Pierce Dalton2,Kim Kee D.3,Hisey Michael S.4,Jackson Robert J.5,Bae Hyun W.6,Hoffman Gregory A.7,Gaede Steven E.8,Danielson Guy O.9,Gordon Charles9,Stone Marcus B.2

Affiliation:

1. Greater Baltimore Neurosurgical Associates, Baltimore, Maryland;

2. Spine Institute of Louisiana, Shreveport, Louisiana;

3. Department of Neurological Surgery, University of California, Davis, Sacramento, California;

4. Texas Back Institute, Plano, Texas;

5. Orange County Neurosurgical Associates, Laguna Hills, California;

6. Cedars-Sinai Spine Center, Los Angeles, California;

7. Orthopaedics Northeast, Fort Wayne, Indiana;

8. Oklahoma Brain and Spine Institute, Tulsa, Oklahoma; and

9. Precision Spine Care, Tyler, Texas

Abstract

OBJECT The purpose of this study was to evaluate the safety and effectiveness of 2-level total disc replacement (TDR) using a Mobi-C cervical artificial disc at 48 months' follow-up. METHODS A prospective randomized, US FDA investigational device exemption pivotal trial of the Mobi-C cervical artificial disc was conducted at 24 centers in the US. Three hundred thirty patients with degenerative disc disease were randomized and treated with cervical total disc replacement (225 patients) or the control treatment, anterior cervical discectomy and fusion (ACDF) (105 patients). Patients were followed up at regular intervals for 4 years after surgery. RESULTS At 48 months, both groups demonstrated improvement in clinical outcome measures and a comparable safety profile. Data were available for 202 TDR patients and 89 ACDF patients in calculation of the primary endpoint. TDR patients had statistically significantly greater improvement than ACDF patients for the following outcome measures compared with baseline: Neck Disability Index scores, 12-Item Short Form Health Survey Physical Component Summary scores, patient satisfaction, and overall success. ACDF patients experienced higher subsequent surgery rates and displayed a higher rate of adjacent-segment degeneration as seen on radiographs. Overall, TDR patients maintained segmental range of motion through 48 months with no device failure. CONCLUSIONS Four-year results from this study continue to support TDR as a safe, effective, and statistically superior alternative to ACDF for the treatment of degenerative disc disease at 2 contiguous cervical levels. Clinical trial registration no.: NCT00389597 (clinicaltrials.gov)

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3