Abstract

OBJECTIVEThe object of this study was to compare the safety and accuracy of pedicle screw placement using the TiRobot system versus conventional fluoroscopy in thoracolumbar spinal surgery.METHODSPatients with degenerative or traumatic thoracolumbar spinal disorders requiring spinal instrumentation were randomly assigned to either the TiRobot-assisted group (RG) or the freehand fluoroscopy-assisted group (FG) at a 1:1 ratio. The primary outcome measure was the accuracy of screw placement according to the Gertzbein-Robbins scale; grades A and B (pedicle breach < 2 mm) were considered clinically acceptable. In the RG, discrepancies between the planned and actual screw placements were measured by merging postoperative CT images with the trajectory planning images. Secondary outcome parameters included proximal facet joint violation, duration of surgery, intraoperative blood loss, conversion to freehand approach in the RG, postoperative hospital stay, and radiation exposure.RESULTSA total of 1116 pedicle screws were implanted in 234 patients (119 in the FG, and 115 in the RG). In the RG, 95.3% of the screws were perfectly positioned (grade A); the remaining screws were graded B (3.4%), C (0.9%), and D (0.4%). In the FG, 86.1% screws were perfectly positioned (grade A); the remaining screws were graded B (7.4%), C (4.6%), D (1.4%), and E (0.5%). The proportion of clinically acceptable screws was significantly greater in the RG than in the FG (p < 0.01). In the RG, the mean deviation was 1.5 ± 0.8 mm for each screw. The most common direction of screw deviation was lateral in the RG and medial in the FG. Two misplaced screws in the FG required revision surgery, whereas no revision was required in the RG. None of the screws in the RG violated the proximal facet joint, whereas 12 screws (2.1%) in the FG violated the proximal facet joint (p < 0.01). The RG had significantly less blood loss (186.0 ± 255.3 ml) than the FG (217.0 ± 174.3 ml; p < 0.05). There were no significant differences between the two groups in terms of surgical time and postoperative hospital stay. The mean cumulative radiation time was 81.5 ± 38.6 seconds in the RG and 71.5 ± 44.2 seconds in the FG (p = 0.07). Surgeon radiation exposure was significantly less in the RG (21.7 ± 11.5 μSv) than in the FG (70.5 ± 42.0 μSv; p < 0.01).CONCLUSIONSTiRobot-guided pedicle screw placement is safe and useful in thoracolumbar spinal surgery.Clinical trial registration no.: NCT02890043 (clinicaltrials.gov)

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3