Safety of coiling with stent placement for the treatment of ruptured wide-necked intracranial aneurysms: a contemporary cohort study in a high-volume center after improvement of skills and strategy

Author:

Zuo Qiao,Yang Pengfei,Lv Nan,Huang Qinghai,Zhou Yu,Zhang Xiaoxi,Duan Guoli,Wu Yina,Xu Yi,Hong Bo,Zhao Rui,Li Qiang,Fang Yibin,Zhao Kaijun,Dai Dongwei,Liu Jianmin

Abstract

OBJECTIVEThe authors compared the contemporary perioperative procedure-related complications between coiling with stent placement and coiling without stent placement for acutely ruptured aneurysms treated in a single center after improvement of interventional skills and strategy.METHODSIn an institutional review board–approved protocol, 133 patients who underwent coiling with stent placement and 289 patients who underwent coiling without stent placement from January 2012 to December 2014 were consecutively reviewed retrospectively. Baseline characteristics, procedure-related complications and mortality rate, angiographic follow-up results, and clinical outcomes were compared between the two groups. Univariate analysis and logistic regression analysis were performed to determine the association of procedure-related complications of coiling with stent placement with potential risk factors.RESULTSThe coiling/stent group and coiling/no-stent group were statistically comparable with respect to all baseline characteristics except for aneurysm location (p < 0.001) and parent artery configuration (p = 0.024). The immediate embolization results and clinical outcomes between the two groups showed no significant differences (p = 0.807 and p = 0.611, respectively). The angiographic follow-up results of the coiling in stent group showed a significant higher occlusion rate and lower recurrence rate compared with the coiling/no-stent group (82.5% vs 66.7%, 3.5% vs 14.5%, p = 0.007). Procedure-related intraoperative rupture and thrombosis, postoperative early rebleeding and thrombosis, and external ventricular drainage–related hemorrhagic event occurred in 3.0% (4 of 133), 2.3% (3 of 133), 1.5% (2 of 133), 0.7% (1 of 133), and 0.8% (1 of 133) of the coiling/stent group compared with 1.0% (3 of 289), 1.4% (4 of 289), 1.4% (4 of 289), and 0.7% (2 of 289) of the coiling/no-stent group, respectively (p = 0.288, p = 0.810, p = 1.000, p = 0.315, and p = 1.000, respectively). One patient presented with coil protrusion in the group of coiling without stent. The procedure-related mortality was 1.5% (2 of 133) in the coiling/stent group and 0.7% in the coiling/no-stent group (p = 0.796). Multivariable analysis showed no significant predictors for the total perioperative procedure-related complications, hemorrhagic complications, or ischemic complications.CONCLUSIONSThe perioperative procedure-related complications and mortality rate did not differ significantly between the coiling/stent group and the coiling/no-stent group for patients with acutely ruptured aneurysms. Considering the better angiographic follow-up results, coiling with stent placement might be a feasible, safe, and promising option for treatment in the acute phase of selected wide-necked ruptured intracranial aneurysms.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3