Object The design of the Leksell Gamma Knife Perfexion facilitates stereotactic radiosurgery (SRS) on cervical spine targets provided that the target itself is located superior to the standard G stereotactic head frame base ring and does not move. This study was designed to measure potential deviations of targets in the upper cervical spine while using the currently available Leksell Coordinate Frame G. Methods A commercially available skull-and–cervical spine model was adapted for SRS using the Leksell Gamma Knife Perfexion. The Leksell Coordinate Frame G was attached to the model, and both CT and fluoroscopic imaging were performed to determine the potential for target deviation at standard Gamma Knife treatment angles of 70°, 90°, and 110°. In addition, target deviations observed at various heights of the patient positioning table were analyzed using a pair of orthogonal fluoroscopic images obtained at a standard 90° gamma angle and compared with target position as it relates to a reference bed height of 4.5 cm. Results An examination of multiple radiopaque targets embedded in or affixed to the model showed target deviations ranging from as low as 3.53 mm at the medial occiput–C1 junction to 15.56 mm at the C3–4 level during 70° extension. Target deviations at 110° flexion relative to targets on a 90° CT scan included deviations ranging from 0.58 mm at the medial occiput–C1 junction to 13.32 mm at the medial C3–4 level. Relative to targets observed at the Perfexion table height of 4.5 cm, target deviation at a table height of 3 cm varied from 0.44 to 5.26 mm. At a table height of 5.5 cm, target deviation varied from 0.44 to 3.60 mm, and at a maximum height of 5.8 cm, target deviation varied from 0.62 to 4.30 mm. Conclusions Target deviation grossly exceeded clinical tolerance and was greater the farther the distance between the cranial base and the cervical spine target. Simple and reproducible methods that allow SRS centers to immobilize the patient's cervical spine using the currently available model G head frame are necessary to increase the range of targets that can be treated safely using the Leksell Gamma Knife Perfexion.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3