Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial

Author:

Jenny HillaryORCID,Reategui Via y Rada MariaORCID,Yesantharao PoojaORCID,Xun HelenORCID,Redett RichardORCID,Sacks Justin MichaelORCID,Yang RobinORCID

Abstract

Background The American College of Surgeons reports 88,320 intraoperative needlestick injuries (NSIs) per year, resulting in US $376 to US $2456 in costs per NSI. Engineered sharps injury prevention (ESIP) devices protect against NSIs. To our knowledge, no study has been published to date to demonstrate clinical effectiveness of an intraoperative ESIP device. Operative Armour is a wearable arm cuff that can be donned during surgical closure to allow surgeons to keep a suture pack and sharps protection container on their forearm. Objective We characterize Operative Armour’s ESIP device effectiveness in a tertiary hospital, hypothesizing that this device will decrease NSI risk by decreasing behaviors associated with NSIs: needle passing and handling. Methods A prospective case-control study was conducted with institutional review board quality improvement designation in which authors observed skin closures of plastic surgery procedures. To ensure accuracy, one surgeon was observed at a time. Control surgeries were purely observational; intervention cases involved surgeon use of the device during skin closure. Outcomes of interest included needle passing, needle handling, lost needles, and loaded waiting needles. Results Surgeons were observed in 50 control and 50 intervention cases. Operative Armour eliminated needle passing during skin closure. One NSI occurred in one control case; no NSIs were observed in intervention cases (P=.36). The mean number of loaded and unprotected waiting needles was also significantly decreased in the intervention group from 2.3 to 0.2 (P<.001). Furthermore, a multivariable linear regression established that Operative Armour significantly decreased the number of needle adjustments by hand per stitch observed (F4, 21.68=3.72; P=.01). In fact, needle adjustments by hand decreased overall (1 adjustment per 10 stitches vs 1 adjustment per 5 stitches, P=.004), and adjustments occurred half as frequently with use of Operative Armour in free flap reconstruction (1 adjustment per 10 stitches vs 1 adjustment per 5 stitches, P=.03) and a quarter as frequently in other breast reconstruction cases such as mastopexy (1 adjustment per 20 stitches vs 1 adjustment per 5 stitches, P=.002). Conclusions Operative Armour effectively functions as an ESIP device by decreasing intraoperative needle passing and handling. Although sample size prohibits demonstrating a decrease in NSIs during observed cases, by decreasing behaviors that drive NSI risk, we anticipate an associated decrease in NSIs with use of the device.

Publisher

JMIR Publications Inc.

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Preventing Perioperative Sharps Injuries;AORN Journal;2022-07-26

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3