Risk of Hand or Glove Contamination After Contact With Patients Colonized With Vancomycin-ResistantEnterococcusor the Colonized Patients' Environment

Author:

Hayden Mary K.,Blom Donald W.,Lyle Elizabeth A.,Moore Charity G.,Weinstein Robert A.

Abstract

Objective.To estimate the level of hand or glove contamination with vancomycin-resistant enterococci (VRE) among healthcare workers (HCWs) who touch a patient colonized with VRE and/or the colonized patient's environment during routine care.Design.Structured observational study.Setting.Medical intensive care unit of a 700-bed, tertiary-care teaching hospital.Participants.VRE-colonized patients and their caregivers.Methods.We obtained samples from sites on the intact skin of 22 patients colonized with VRE and samples from sites in the patients' rooms, before and after routine care, during 27 monitoring episodes. A total of 98 unique HCWs were observed during 131 HCW observations. Observers recorded the sites touched by HCWs. Culture samples were obtained from HCWs' hands and gloves before and after care.Results.VRE were isolated from a mean (±SD) of 55% ± 24% of patient sites (n= 256) and 17% ± 12% of environmental sites (n= 1,572). Most HCWs (131 [56%]) touched both the patient and the patient's environment; no HCW touched only the patient. Of 103 HCWs whose hand samples were negative for VRE when they entered the room, 52% contaminated their hands or gloves after touching the environment, and 70% contaminated their hands or gloves after touching the patient and the environment (P= .101). In a univariate logistic regression model, the risk of hand or glove contamination was associated with the number of contacts made (odds ratio, 1.1 [95% confidence interval, 1.01-1.19). In a multivariate model, the effect of the number of contacts could not be distinguished from the effect of type of contact (ie, touching the environment alone or touching both the patient and the environment). Overall, 37% of HCWs who did not wear gloves contaminated their hands, and 5% of HCWs who wore gloves did so (an 86% difference).Conclusion.HCWs were nearly as likely to have contaminated their hands or gloves after touching the environment in a room occupied by a patient colonized by VRE as after touching the colonized patient and the patient's environment. Gloves were highly protective with respect to hand contamination.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

Reference23 articles.

1. Nosocomial Transmission of Vancomycin-Resistant Enterococci From Surfaces

2. Transfer of Vancomycin-Resistant Enterococci via Health Care Worker Hands

3. Chlorhexidine Gluconate to Cleanse Patients in a Medical Intensive Care Unit

4. Society for Healthcare Epidemiology of America/Association for Professionals in Infection Control//Infectious Diseases Society of America;Boyce;MMWR Recomm Rep,2002

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3