Policies for Endotracheal Suctioning of Patients Receiving Mechanical Ventilation: A Systematic Review of Randomized Controlled Trials

Author:

Niël-Weise B. S.,Snoeren R. L. M. M.,van den Broek P. J.

Abstract

Objective.The Dutch Working Party on Infection Prevention (Werkgroep Infectiepreventie [WIP]) aimed to determine whether certain policies on endotracheal suctioning are better than others in terms of prevention of ventilator-associated pneumonia (VAP) in patients receiving mechanical ventilation in the intensive care unit.Methods.Publications were retrieved by a systematic search of Medline and the Cochrane Library for literature published before February 2006. Additionally, the reference lists of all identified trials were examined. All randomized trials, quasi-randomized trials, and systematic reviews or meta-analyses of randomized or quasi-randomized trials that compared different policies on endotracheal suctioning for patients receiving mechanical ventilation in the intensive care unit were selected. Two reviewers independently assessed trial quality and extracted data. Disagreements were resolved by discussion with a third reviewer. Data from the original publications were used to calculate the relative risk of VAP. Data for VAP were combined in the analysis where appropriate, by use of a random-effects model.Results.Ten trials were included in the review. The quality of the trials and the way they were reported were generally unsatisfactory. Eight low-quality trials indicate that use of closed instead of open suction systems has no effect on the incidence of VAP. Two moderate-quality trials indicate that changing in-line suction catheters less frequently than every 24 hours does not increase the incidence of VAP.Conclusion.The WIP recommends that there be no preferential use of either open or closed endotracheal suction systems to reduce the rate of VAP, but it elucidates that the quality of the evidence is low. Considerations other than prevention of VAP should determine the choice of the suction system. When closed systems are used, the WIP recommends changing the in-line suction catheters every 48 hours. In case of mechanical failure or soiling of the suction system, they may be changed more frequently.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3