Abstract
Steam dryness detection is crucial in the field of oil exploitation. A steam dryness too high will be dangerous, whereas a low steam dryness too low will affect the efficiency of extraction. Therefore, real-time, high-precision detection of steam dryness is essential. The methods for detecting steam dryness include chemical, thermodynamic, radiometric, and microwave. The manual test method possesses the best detection accuracy. However, the real-time performance is not good, and the detection process is cumbersome. This article uses a silver nitrate solution to titrate chloride ions and combine them with the change in the absorbance of the solution to determine the endpoint of the titration. This article reported that the automatic chloride ion concentration measurement was a rep and that the detection of chloride ion concentration was 15 mg l−1. The detection linearity reached 0.992. Therefore, our titration endpoint judgment method has better anti-interference.
Funder
Natural Science Foundation of Beijing Municipality
National Natural Science Foundation of China
Fundamental Research Funds for the Central Universities
Publisher
The Electrochemical Society
Subject
Materials Chemistry,Electrochemistry,Surfaces, Coatings and Films,Condensed Matter Physics,Renewable Energy, Sustainability and the Environment,Electronic, Optical and Magnetic Materials
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献