Comparison of Topographic Technologies in Anterior Surface Mapping of Keratoconus using Two Display Algorithms and Six Corneal Topography Devices

Author:

Roberts Cynthia J,Lembach Richard G,Markakis George A,Harris James W

Abstract

ABSTRACT Purpose To evaluate anterior surface topographic technologies and display algorithms in mapping keratoconus. Materials and methods A total of 27 eyes of 17 subjects clinically diagnosed with keratoconus were imaged on six topographers: EyeSys, Alcon EyeMap, Keratron, TMS-1, Orbscan and PAR corneal topography system. Axial distance (AD) and instantaneous radius of curvature (IROC) algorithms were generated, and the cone apex was determined manually using a cursor. Intermachine comparisons for cone magnitude (steepest curvature), as well as cone location in radius and meridian were performed for each display algorithm using both AD and IROC. Significance (p < 0.05) was determined using repeated measures analysis of variance (ANOVA) on successive mean values. Maps were also evaluated for processability, defined by the ability to reconstruct a reasonable map for each subject, not map quality. Results There were no significant differences between successive means for cone location in either radial or meridional directions. For AD, Orbscan was greater than both small mire Placido devices (Keratron and TMS-1), which were not different from each other. The small mire devices had significantly greater curvature magnitude than the large mire placido devices (EyeSys, Alcon EyeMap) which were not different from each other. Finally, PAR was significantly lower than the large mire Placido devices. For IROC, the pattern was the same with the exception that the Orbscan was not different than the small mire Placido devices in curvature magnitude. For processing success, the PAR had 100% processability, and all other devices were between 73 and 77%. Conclusion In monitoring keratoconus, evaluation of change over time is fundamental to treatment decisions, making understanding of topographic technology differences in mapping keratoconic corneas extremely important. How to cite this article Markakis GA, Roberts CJ, Harris JW, Lembach RG. Comparison of Topographic Technologies in Anterior Surface Mapping of Keratoconus using Two Display Algorithms and Six Corneal Topography Devices. Int J Kerat Ect Cor Dis 2012;1(3):153-157.

Publisher

Jaypee Brothers Medical Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3