Endobronchial Valve (Zephyr) Treatment in Homogeneous Emphysema: One-Year Results from the IMPACT Randomized Clinical Trial

Author:

Eberhardt Ralf,Slebos Dirk-Jan,Herth Felix J.F.,Darwiche KaidORCID,Wagner Manfred,Ficker Joachim H.ORCID,Petermann Christoph,Hübner Ralf-Harto,Stanzel Franz,Shargill Narinder S.ORCID,Valipour Arschang,

Abstract

<b><i>Rationale:</i></b> The long-term safety and effectiveness of bronchoscopic lung volume reduction with Zephyr endobronchial valves in subjects with severe homogeneous emphysema with little to no collateral ventilation beyond 3 months have yet to be established. <b><i>Methods:</i></b> Ninety-three subjects were randomized to either bronchoscopic lung volume reduction with Zephyr valves or standard of care (SoC) (1:1). Zephyr valve subjects were assessed at 3, 6, and 12 months. SoC subjects were assessed at 3 and 6 months; they were then offered crossover to Zephyr valve treatment. <b><i>Results:</i></b> The mean group difference (Zephyr valve – SoC) for change in FEV<sub>1</sub> from baseline to 6 months was 16.3 ± 22.1% (mean ± SD; <i>p</i> &#x3c; 0.001). Secondary outcomes showed the mean between-group difference for the six-minute walk distance of +28.3 ± 55.3 m (<i>p</i> = 0.016); St. George’s Respiratory Questionnaire, −7.51 ± 9.56 points (<i>p</i> &#x3c; 0.001); modified Medical Research Council, −0.42 ± 0.81 points (<i>p</i> = 0.019); BODE index, −0.85 ± 1.39 points (<i>p</i> = 0.006); and residual volume of −430 ± 830 mL (<i>p</i> = 0.011) in favor of the Zephyr valve group. At 6 months, there were significantly more responders based on the minimal clinically important difference for these same measures in the Zephyr valve versus the SoC group. The clinical benefits were persistent at 12 months. The percentage of subjects with respiratory serious adverse events was higher in the Zephyr valve group compared to SoC during the first 30 days post-procedure but not statistically different for the Zephyr valve and SoC groups from 31 days to 6 months, and stable in the Zephyr valve group out to 12 months. There were 2 deaths in the SoC group in the 31-day to 6-month period and none in the Zephyr valve group out to 12 months. <b><i>Conclusions:</i></b> Bronchoscopic lung volume reduction with Zephyr valves in subjects with severe homogeneous emphysema and little to no collateral ventilation provides clinically meaningful change from baseline in lung function, quality of life, exercise capacity, dyspnea, and the BODE index at 6 months, with benefits maintained out to 12 months.

Publisher

S. Karger AG

Subject

Pulmonary and Respiratory Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3