The Influence of the Learning Curve on Clinical Outcomes in Balloon-Expandable versus Self-Expandable Transfemoral Transcatheter Aortic Valve Implantation

Author:

Istrate Mihnea,Dregoesc Mihaela IoanaORCID,Bolboaca Sorana D.ORCID,Solomonean Aurelia G.,Botis Catalin,Stef Adrian,Hagiu Radu,Moț Ștefan D.C.,Bindea Dan I.,Oprea Alexandru,Trifan Cătălin A.,Iancu Adrian C.ORCID

Abstract

<b><i>Introduction:</i></b> Balloon-expandable (BE) and self-expandable (SE) prostheses are the main types of devices currently used in transcatheter aortic valve implantation (TAVI). Despite the different designs, clinical practice guidelines do not make any specific recommendation on the selection of one device over the other. Most operators are trained in using both BE and SE prostheses, but operator experience with each of the two designs might influence patient outcomes. The aim of this study was to compare the immediate and mid-term clinical outcomes during the learning curve in BE versus SE TAVI. <b><i>Methods:</i></b> The transfemoral TAVI procedures performed in a single center between July 2017 and March 2021 were grouped according to the type of implanted prosthesis. The procedures in each group were ordered according to the case sequence number. For each patient, a minimum follow-up time of 12 months was required for inclusion in the analysis. The outcomes of the BE TAVI procedures were compared with the outcomes of the SE TAVI procedures. Clinical endpoints were defined according to the Valve Academic Research Consortium 3 (VARC-3). <b><i>Results:</i></b> The median follow-up time was 28 months. Each device group included 128 patients. In the BE group, case sequence number predicted mid-term all-cause mortality at an optimal cutoff value ≤58 procedures (AUC 0.730; 95% CI: 0.644–0.805; <i>p</i> &lt; 0.001), while in the SE group, the cutoff value was ≤85 procedures (AUC 0.625; 95% CI: 0.535–0.710; <i>p</i> = 0.04). A direct comparison of the AUC showed that case sequence number was equally adequate in predicting mid-term mortality, irrespective of prosthesis type (<i>p</i> = 0.11). A low case sequence number was associated with an increased rate of VARC-3 major cardiac and vascular complications (OR 0.98 95% CI: 0.96–0.99; <i>p</i> = 0.03) in the BE device group, and with an increased rate of post-TAVI aortic regurgitation ≥ grade II (OR 0.98; 95% CI: 0.97–0.99; <i>p</i> = 0.03) in the SE device group. <b><i>Conclusions:</i></b> In transfemoral TAVI, case sequence number influenced mid-term mortality irrespective of prosthesis type, but the learning curve was longer in the case of SE devices.

Publisher

S. Karger AG

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3