Efficacy and Safety of CT-Guided Kidney Biopsy for the Diagnosis of Glomerular Diseases in Complicated Patients

Author:

Vian Javier,Shabaka AmirORCID,Lallena Silvia,Gatius Serena,Lopez de la Manzanara Virginia,Barrera-Ortega JeronimoORCID,Méndez-Fernández Ramiro J.

Abstract

<b><i>Introduction:</i></b> Kidney biopsy is the cornerstone for the diagnosis of glomerular diseases and to guide treatment. Percutaneous ultrasound-guided kidney biopsy is currently the gold standard to obtain cortical specimens. However, in cases where ultrasound-guided kidney biopsy is not deemed safe (obese patients, deep kidneys, or kidneys with a complicated anatomy), CT-guided kidney biopsy could be a convenient alternative to obtain renal tissue samples. The aim of this study was to describe the diagnostic yield and complications of CT-guided kidney biopsies in patients with glomerular diseases that were previously discarded for ultrasound-guided kidney biopsy. <b><i>Material and Methods:</i></b> We performed a retrospective, single-center, observational study including patients who underwent CT-guided native kidney biopsies in our center after being contraindicated for ultrasound-guided biopsy. Patients’ records were reviewed retrieving baseline characteristics and pre-biopsy clinical, laboratory parameters and concomitant medication. The biopsy needle gauge, site of puncture, and number of needle passes were recorded. The diagnostic yield was evaluated by the number of glomeruli obtained, the rate of specimens that were adequate to reach diagnosis, and the number of biopsies that had to be repeated. Complications were defined as minor (hypotension, hematoma) and major (arteriovenous fistulae, major bleeding requiring embolization, or nephrectomy). The diagnostic yield and complications were compared to ultrasound-guided native kidney biopsies performed during the same period. <b><i>Results:</i></b> 56 CT-guided native kidney biopsies were performed during the study period. The number of glomeruli obtained per patient was 11.5 ± 6.3, which was inferior to that obtained from ultrasound-guided biopsies (14.08 ± 8.47, <i>p</i> &lt; 0.05). However, the rate of specimens that were adequate to reach a diagnosis was similar (92.9% vs. 90.8%, <i>p</i> = 0.437). The number of needle passes was higher in CT-guided kidney biopsies (2.0 ± 0.7 vs. 1.7 ± 0.5, <i>p</i> &lt; 0.05), as well as the incidence of post-biopsy perirenal asymptomatic hematomas (66.1% vs. 24.5%, <i>p</i> &lt; 0.01). There were no significant differences in other post-biopsy minor complications (1.8% vs. 2.5%, <i>p</i> = 0.621). There were no major complications after CT-guided kidney biopsies. <b><i>Conclusions:</i></b> CT-guided percutaneous kidney biopsy is a valid alternative for the diagnosis of glomerular diseases in patients with special characteristics such as obesity or deep kidneys that contraindicate ultrasound-guided biopsy. In this population, CT-guided kidney biopsies are safe and provide a high diagnostic yield, reaching a diagnosis in &gt;90% of patients that had been previously discarded for ultrasound-guided biopsy.

Publisher

S. Karger AG

Reference16 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3