Background— Detection of cardiac recovery that allows long-term cardiac stability after ventricular assist device (VAD) explantation is a major goal. After normalization of ventricular diameters during unloading, the pre-explant left ventricular ejection fraction (LVEF) allows the detection of patients with the potential to remain stable after VAD explantation. However, some patients with LVEF >45 before VAD explantation show early recurrence of heart failure (HF). We aimed to find out if unstable improvement can be recognized before VAD explantation. Methods and Results— Among 96 patients weaned from VADs since 1995, a relatively homogenous group of 53 patients with nonischemic chronic cardiomyopathy (CCM) was selected for the study. The pre-explant stability of major parameters of LV function, size, and geometry that were measured by echocardiography during serial “off-pump” trials was tested for relationship with cardiac stability after VAD explantation. LVEF, systolic peak wall motion velocity (Sm), end-diastolic diameter (LVEDD), end-diastolic relative wall thickness (RWT ED ) and end-diastolic short/long-axis ratio (S/L ED ) were selected for evaluation. In postweaning unstable patients, the selected parameters showed relevant instability already before VAD explantation during the time period between best cardiac improvement and VAD explantation and also during the final off-pump trial just before VAD explantation. For all parameters, there were significant differences ( P <0.05) in pre-explant changes between patients with and without postweaning cardiac stability. Using the optimal cutoff values obtained from receiver-operating characteristic analysis, we found for our selected parameters predictive values for postexplant cardiac stability of ≥1 year, ≥3 years, and ≥5 years, ranging between 94 and 100, 92, and 100, and 78 and 100, respectively. Using for all parameter changes the cutoff value of 10, we found similar predictive values for cardiac stability of ≥1 year, ≥3 years, and ≥5 years, ranging between 93 and 97, 90 and 96, and 83 and 92, respectively. Conclusions— Our results strongly suggest the possibility to improve the prediction of postexplant transplant/VAD-free outcome in CCM patients with cardiac improvement during VAD support by analyzing the pre-explant stability of several LV off-pump echocardiographic parameters during serial off-pump trials.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 56 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3