Agreement Between Guideline Thresholds Using an “All‐in‐One” Device to Measure Office, Home, and Ambulatory Blood Pressures

Author:

Kario Kazuomi1ORCID,Tomitani Naoko1ORCID,Hoshide Satoshi1,Nishizawa Masafumi2,Yoshida Tetsuro3ORCID,Kabutoya Tomoyuki1ORCID,Fujiwara Takeshi1ORCID,Mizuno Hiroyuki1ORCID,

Affiliation:

1. Division of Cardiovascular Medicine, Department of Medicine Jichi Medical University School of Medicine Tochigi Japan

2. Minamisanriku Hospital Motoyoshi‐gun Miyagi Japan

3. Onga Nakama Medical Association Onga Hospital Fukuoka Japan

Abstract

Background Blood pressure (BP) thresholds for diagnosing and managing hypertension vary for office, home, and ambulatory readings, and between guideline documents. This analysis determined corresponding office, home, and ambulatory BP thresholds using baseline data from the HI‐JAMP (Home‐Activity Information and Communication Technology–Based Japan Ambulatory Blood Pressure Monitoring Prospective) study, which used a validated “all‐in‐one” BP monitoring device. Methods and Results Data from 2322 treated patients with hypertension who underwent office BP measurement, then 24‐hour ambulatory BP monitoring, then home BP monitoring for 5 days were analyzed. Corresponding BP thresholds for office, home, and ambulatory measurements were determined using Deming regression. Values equivalent to office systolic BP (SBP) of 120 and 140 mm Hg were as follows: 115.9 and 127.7 mm Hg for 24‐hour ambulatory SBP; 120.8 and 134.0 mm Hg for daytime ambulatory SBP; 104.9 and 117.9 mm Hg for nighttime ambulatory SBP; and 122.0 and 134.2 mm Hg for morning‐evening average home SBP. Deming regression showed that morning‐evening average home SBP and daytime ambulatory SBP were almost the same (home SBP=0.99×daytime ambulatory SBP+0.27 mm Hg; r =0.627). Morning‐evening average home SBP values of 120 and 135 mm Hg were equivalent to daytime ambulatory SBP values of 119.1 and 133.9 mm Hg, respectively. A home SBP threshold of 130 mm Hg corresponded to 24‐hour and nighttime ambulatory SBP values of 123.5 and 113.6 mm Hg, whereas a home SBP threshold of 135 mm Hg corresponded to 24‐hour and nighttime ambulatory SBP values of 128.0 and 119.2 mm Hg. Conclusions Ambulatory and home BP thresholds in this analysis were similar to those proposed by existing guidelines. The similarity between the home BP and daytime ambulatory BP thresholds was a clinically relevant finding.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Mean‐ing Beyond Office Blood Pressure;Journal of the American Heart Association;2023-12-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3