Accuracy of Measurements of the Structural Reserve for Upper Limb Function in Patients With Moderate-to-Severe Stroke

Author:

Yoo Yeun Jie1,Jun So Yeon2ORCID,Park Eun Jin3ORCID,Kim Youngkook3ORCID

Affiliation:

1. Department of Rehabilitation Medicine, St Vincent’s Hospital (Y.J.Y.), College of Medicine, The Catholic University of Korea, Seoul.

2. Department of Rehabilitation Medicine, Seoul St Mary’s Hospital (S.Y.J.), College of Medicine, The Catholic University of Korea, Seoul.

3. Department of Rehabilitation Medicine, Yeouido St Mary’s Hospital (E.J.P., Y.K.), College of Medicine, The Catholic University of Korea, Seoul.

Abstract

BACKGROUND: The structural integrity of the corticospinal tract (CST) is an important biomarker of poststroke upper limb recovery. Injured CST undergoes Wallerian degeneration rostrocaudally during the first few months. However, there is no standardized measurement of the structural integrity of the CST. This study aimed to determine the measurement accuracy of the structural integrity of the CST. METHODS: This cross-sectional study included 50 consecutive patients with middle cerebral artery stroke who underwent diffusion tensor imaging upon transfer from the acute stroke unit to the inpatient rehabilitation facility (2018–2022). We evaluated hemiplegic upper limb function using Shoulder Abduction and Finger Extension (SAFE) scores. Fractional anisotropy values representing the structural integrity of the CST were evaluated using 4 region of interest-based and 2 tract-based measurements, including the posterior limb of internal capsule, cerebral peduncle, pons, pontomedullary junction, entire CST, and CST in the brainstem. Multivariate linear regression models and the area under the curve (AUC) were used to determine measurement accuracy for hemiplegic upper limb function. RESULTS: The structural integrity of the CST at the pontomedullary junction showed the highest explanatory power, followed by the entire CST, in the multivariate linear regression models (adjusted R 2 = 0.459 and 0.425, respectively). The structural integrity of the CST at the pontomedullary junction also showed the highest AUC, followed by the entire CST, in discriminating patients with a SAFE score of <8 or 5 from those with SAFE ≥8 or 5 (SAFE <8: AUC, 0.90 [95% CI, 0.80–1.00]; AUC, 0.83 [0.66–0.99]; SAFE <5: AUC, 0.87 [0.77–0.96]; AUC, 0.83, [0.72–0.95], respectively). CONCLUSIONS: The structural integrity of the CST measured at the pontomedullary junction or entire CST demonstrated the highest accuracy for hemiplegic upper limb function in the subacute phase of stroke.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3