Comparison of Transcranial Doppler Ultrasonography and Transesophageal Echocardiography to Monitor Emboli During Coronary Artery Bypass Surgery

Author:

Barbut D.1,Yao F.S.1,Hager D.N.1,Kavanaugh P.1,Trifiletti R.R.1,Gold J.P.1

Affiliation:

1. From the Departments of Neurology (D.B., P.K., R.T., D.H.), Cardiothoracic Anesthesia (F.Y.), and Cardiothoracic Surgery (J.G.), Cornell University Medical College, New York, NY.

Abstract

Background and Purpose Transcranial Doppler ultrasonography (TCD) is the standard technique for monitoring emboli in the cerebral circulation. Embolic signals have been detected with the use of this technique in most patients undergoing coronary artery bypass surgery. We previously reported that the majority of emboli are detected after release of aortic cross-clamps and partial occlusion clamps. In this study we compare the intraoperative use of TCD with transesophageal echocardiography (TEE) to monitor cerebral emboli. Methods We simultaneously monitored 20 patients undergoing coronary bypass surgery with TCD and TEE. All patients also underwent routine TEE examination of the aorta. Results Embolic signals were detected in all patients by both techniques. Mean total number of emboli was 535±109 by TEE compared with 133±28 by TCD. We found correlation between numbers of emboli detected by the two techniques at clamp placement and release ( r =.65, P =.002). Clamp placement and release accounted for 84% of all emboli by TEE and 83% by TCD. By TEE, large, highly echogenic particles were detected after clamp release compared with small, barely echo-dense particles at the onset of bypass. No such distinction was apparent by TCD. We found correlation between severity of aortic atheroma and both TEE- ( P =.003) and TCD-detected ( P =.009) emboli. Conclusions TEE and TCD can both be used to continuously monitor emboli during coronary artery bypass surgery. However, TEE is invasive and justified only if it is being performed for intraoperative assessment of aortic atheromatosis or cardiac function.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3