Correlation of Peak Systolic Velocity and Angiographic Measurement of Carotid Stenosis Revisited

Author:

Alexandrov Andrei V.1,Brodie Dianne S.1,McLean Arline1,Hamilton Paul1,Murphy John1,Burns Peter N.1

Affiliation:

1. the Neurovascular Doppler Laboratory (A.V.A., D.S.B., A.M., P.H.) and the Departments of Neurology (A.V.A., A.M.), Radiology (P.H., J.M.), and Imaging Research (P.N.B.), Sunnybrook Health Science Center, University of Toronto, Canada.

Abstract

Background and Purpose Recent observations from the North American Symptomatic Carotid Endarterectomy Trial (NASCET) questioned the reliability of peak systolic velocity (PSV) criteria for grading carotid stenosis. We compared PSV and angiographic measurements at our center together with known physiological relationships to investigate the accuracy of ultrasound. Methods Consecutive patients who underwent both color-coded duplex ultrasound and intra-arterial digital subtraction angiography were studied. PSV was determined with angle correction at the site of the tightest internal carotid artery narrowing. Carotid stenosis was measured on angiograms with the North American (N) and common carotid (C) methods. Variables for the stepwise multiple linear regression analysis were selected from an axisymmetrical flow model. Results Eighty bifurcations were imaged in 40 patients. PSV did not exceed 140 cm/s in normal vessels. In diseased arteries, PSV increased proportionally with increasing stenosis and decreased to 0 cm/s at occlusion. In stepwise selection of polynomial terms, the linear, quadratic, and cubic correlations of .38, .17, and .22 for N and .45, .24, and .03 for C were found to be significant ( P <.02). When only stenosed vessels were evaluated, PSV increase was found with greater scatter for the N measurement: r 2 =.73 for N and r 2 =.85 for C (n=50; P =.03 for the difference between two correlated correlation coefficients). Conclusions At our laboratory PSV consistently correlates well with N and C angiographic measurements, as determined with a simple flow model. The complex nature of these correlations and greater variability of the N measurement should be taken into account when data from different centers are compared.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3