Reproducibility of noninvasive ultrasonic measurement of carotid atherosclerosis. The Asymptomatic Carotid Artery Plaque Study.

Author:

Riley W A1,Barnes R W1,Applegate W B1,Dempsey R1,Hartwell T1,Davis V G1,Bond M G1,Furberg C D1

Affiliation:

1. Department of Neurology, Bowman Gray School of Medicine, Winston Salem, N.C. 27157-1078.

Abstract

To determine the effect of a lipid-lowering agent and/or a low-dose antithrombotic agent on the progression of early-stage carotid atherosclerosis, noninvasive B-mode ultrasound was used to measure intimal-medial thickness in asymptomatic individuals with moderately elevated lipids as part of the ongoing multicenter Asymptomatic Carotid Artery Plaque Study. Uniform ultrasonic scanning and reading protocols were implemented to obtain maximum intimal-medial thickness measurements in 12 standard segments in patients having a small to moderate wall thickness (1.5-3.5 mm) in at least one of the carotid arteries. Paired B-mode image recordings on 858 patients, performed 1 month apart and read at a core laboratory (each pair by the same reader), determined both within-sonographer (W, n = 405) and between-sonographer (B, n = 453) reproducibility. The primary end point (mean +/- SD), defined in each individual as the mean value of the 12 maximum intimal-medial thickness measurements, was 1.31 +/- 0.21 mm (W) and 1.32 +/- 0.22 (B) at the time of the second examination. The mean difference in the primary end point (exam 2-exam 1) was -0.01 +/- 0.13 mm (W) and 0.00 +/- 0.15 mm (B). The Pearson correlation coefficients were 0.79 (W) and 0.75 (B). In 90% of the patients, the absolute difference in the primary end point was less than 0.22 mm (W) and less than 0.24 mm (B). Variability of the secondary end point, defined as the single largest intimal-medial thickness measurement in a patient, was between three and four times larger than the variability for the primary end point. Differences in sonographer performance between clinical centers were very small. The results demonstrate that standardized noninvasive ultrasonic techniques yield highly reproducible measures of carotid intimal-medial thickness, which can serve as a measure of carotid atherosclerosis in clinical trials that monitor small rates of lesion progression.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 189 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3