Multicenter Evaluation of the Feasibility of Clinical Implementation of SPECT Myocardial Blood Flow Measurement: Intersite Variability and Imaging Time

Author:

Wells R. Glenn1ORCID,Bengel Frank M.2ORCID,Camoni Luca3ORCID,Cerudelli Elisabetta3ORCID,Cuddy-Walsh Sarah G.1,Diekmann Johanna2ORCID,Han Lewis1,Kadoya Yoshito1ORCID,Kawaguchi Naoto4,Keng Yung Jih Felix5,Miyagawa Masao4ORCID,Ratner Hagit6,Teng Xue Fen5,Ruddy Terrence D.1ORCID

Affiliation:

1. Cardiology, University of Ottawa Heart Institute, Ottawa, Canada (R.G.W., S.G.C.-W., L.H., Y.K., T.D.R.).

2. Medizinische Hochschule Hannover, Hannover, Germany (F.M.B., J.D.).

3. Nuclear Medicine, Università & Spedali Civili, Brescia, Italy (L.C., E.C.).

4. Department of Radiology, Ehime University Graduate School of Medicine, Ehime, Japan (N.K., M.M.).

5. Cardiology, National Heart Center Singapore, Singapore (Y.J.F.K., X.F.T.).

6. GE Healthcare, Haifa, Israel (H.R.).

Abstract

Background: Single-center studies have shown that single photon emission computed tomography myocardial blood flow (MBF) measurement is accurate compared with MBF measured with microspheres in a porcine model, positron emission tomography, and angiography. Clinical implementation requires consistency across multiple sites. The study goal is to determine the intersite processing repeatability of single photon emission computed tomography MBF and the additional camera time required. Methods: Five sites (Canada, Italy, Japan, Germany, and Singapore) each acquired 25 to 35 MBF studies at rest and with pharmacological stress using technetium-99m-tetrofosmin on a pinhole-collimated cadmium-zinc-telluride–based cardiac single photon emission computed tomography camera with standardized list-mode imaging and processing protocols. Patients had intermediate to high pretest probability of coronary artery disease. MBF was measured locally and at a core laboratory using commercially available software. The time a room was occupied for an MBF study was compared with that for a standard rest/stress myocardial perfusion study. Results: With motion correction, the overall correlation in MBF between core laboratory and local site was 0.93 (range, 0.87–0.97) at rest, 0.90 (range, 0.84–0.96) at stress, and 0.84 (range, 0.70–0.92) for myocardial flow reserve. The local-to-core difference in global MBF (bias -MBF ) was 5.4% (−3.8% to 14.8%; median [interquartile range]) at rest and 5.4% (−6.2% to 19.4%) at stress. Between the 5 sites, bias -MBF ranged from −1.6% to 11.0% at rest and from −1.9% to 16.3% at stress; the interquartile range in bias -MBF was between 9.3% (4.8%–14.0%) and 22.3% (−10.3% to 12.0%) at rest and between 17.0% (−11.3% to 5.6%) and 33.3% (−10.4% to 22.9%) at stress and was not significantly different between most sites. Both bias and interquartile range were like previously reported interobserver variability and less than the SD of the test-retest difference of 30%. The overall difference in myocardial flow reserve was 1.52% (−10.6% to 11.3%). There were no significant differences between with and without motion correction. The average additional acquisition time varied between sites from 44 to 79 minutes. Conclusions: The average bias -MBF and bias -MFR values were small with standard deviations substantially less than the test-retest variability. This demonstrates that MBF can be measured consistently across multiple sites and further supports that this technique can be reliably implemented. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03427749.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3