Ultrasound-Enhanced Thrombolytic Effect of Tissue Plasminogen Activator–Loaded Echogenic Liposomes in an In Vivo Rabbit Aorta Thrombus Model—Brief Report

Author:

Laing Susan T.1,Moody Melanie1,Smulevitz Beverly1,Kim Hyunggun1,Kee Patrick1,Huang Shaoling1,Holland Christy K.1,McPherson David D.1

Affiliation:

1. From the Division of Cardiology, Department of Internal Medicine, University of Texas Health Science Center at Houston, Houston, TX (S.T.L., M.M., B.S., H.K., P.K., S.H., D.D.M.); Division of Cardiovascular Diseases, Department of Internal Medicine (C.K.H.) and Department of Biomedical Engineering (C.K.H.), University of Cincinnati, Cincinnati, OH.

Abstract

Objective— Ultrasound enhances thrombolysis when combined with a thrombolytic and a contrast agent. This study aimed to evaluate the thrombolytic effect of our tissue plasminogen activator (tPA)–loaded echogenic liposomes (ELIP) in an in vivo clot model, with and without ultrasound treatment. Methods and Results— The femoral arteries of New Zealand White rabbits (n=4 per group) were cannulated. The abdominal aortas were denuded, and thrombi were created using a solution of sodium ricinoleate plus thrombin. Rabbits were then randomly selected to receive tPA-loaded ELIP (200 μg of tPA/5 mg of lipid) or empty ELIP with or without pulsed (color) Doppler ultrasound (5.7 MHz) for 2 minutes. Thrombus was imaged and echogenicity analyzed before and after ELIP injection. Blood flow velocities were measured at baseline, after clot formation, and serially after treatment up to 15 minutes. tPA-loaded ELIP highlighted thrombus in the abdominal aorta more effectively than empty ELIP ( P <0.05). Ultrasound enhanced the thrombolytic effect of tPA-loaded ELIP, resulting in earlier and more complete recanalization rates ( P <0.001). Conclusion— This study demonstrates effective highlighting of clots and thrombolytic effect of tPA-loaded ELIP in an in vivo rabbit aorta clot model. Doppler ultrasound treatment enhances this thrombolytic effect, resulting in earlier and more complete recanalization rates.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3