Vasoreactive Response to Maternal Hyperoxygenation in the Fetus With Hypoplastic Left Heart Syndrome

Author:

Szwast Anita1,Tian Zhiyun1,McCann Margaret1,Donaghue Denise1,Rychik Jack1

Affiliation:

1. From The Fetal Heart Program at the Cardiac Center at The Children’s Hospital of Philadelphia (A.S., Z.T., M.M., D.D., J.R.), Philadelphia, Pa; and the Division of Cardiology (A.S., J.R.), Department of Pediatrics, University of Pennsylvania School of Medicine, Philadelphia, Pa.

Abstract

Background— Cardiopulmonary interactions play an important role in the pathophysiology of hypoplastic left heart syndrome (HLHS). Pulmonary vasculopathy has been identified, especially in those with restrictive/intact atrial septum. Responsiveness of the pulmonary vasculature to maternal hyperoxygenation (MH) may provide a tool to assess the degree of pulmonary vasculopathy present before birth. Methods and Results— Doppler echocardiography was performed in 27 normal and 43 HLHS fetuses. In HLHS, sampling was repeated after 10 minutes of MH with 60% FiO 2 and after 5 minutes of recovery. Sampling was performed in the proximal, midportion, and distal branch pulmonary artery (PA). Pulsatility index (PI) was used as a measure of vascular impedance. Of the HLHS fetuses, 34 had an open interatrial septum and 9 had a restrictive/intact atrial septum. At birth, 5 fetuses underwent immediate intervention on the interatrial septum. Middle cerebral artery PI was lower in HLHS versus normal fetuses ( P <0.001). There was no difference in UA, DA, or branch PA PI between normal fetuses and those with HLHS. MH led to a significant decrease in PI at each of the PA sites sampled in fetuses with an open atrial septum ( P <0.001); however, there no was significant change in the PI in fetuses that required immediate intervention on the atrial septum at birth. Using a cutoff value of <10% vasoreactivity, the sensitivity of MH testing for determining need for immediate intervention at birth is 100% (0.46 to 1.0); specificity, 94% (0.78 to 0.99); positive predictive value, 71% (0.30 to 0.95); and negative predictive value, 100% (0.86 to 1.0). No untoward effects were seen with MH. Conclusions— PA vasoreactivity to MH occurs in the fetus with HLHS. MH testing accurately identifies fetuses requiring urgent postnatal intervention at birth and may be used to select candidates for fetal atrial septoplasty.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

Cited by 90 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3