Transcatheter Aortic Valve Implantation for Patients With Severe Bicuspid Aortic Valve Stenosis

Author:

Hayashida Kentaro1,Bouvier Erik1,Lefèvre Thierry1,Chevalier Bernard1,Hovasse Thomas1,Romano Mauro1,Garot Philippe1,Watanabe Yusuke1,Farge Arnaud1,Donzeau-Gouge Patrick1,Cormier Bertrand1,Morice Marie-Claude1

Affiliation:

1. From the Institut Cardiovasculaire Paris Sud, 91300 Massy, France.

Abstract

Background— Bicuspid aortic valve (BAV) is regarded as a relative contraindication to transcatheter aortic valve implantation attributable to the risk of uneven expansion of the bioprosthesis. The purpose of this study was to evaluate the efficacy and safety of transcatheter aortic valve implantation in patients with BAV. Methods and Results— Of 470 patients included in our prospective transcatheter aortic valve implantation database (October 2006–January 2012), 229 consecutive patients undergoing both echocardiography and multidetector computed tomography were analyzed. We compared clinical outcomes in patients with vs patients without BAV. In this series of 229 patients, BAV was detected by multidetector computed tomography in 21 patients (9.2%). BAV was identified by transthoracic and transoesophagal echocardiography in only 9 of these 21 patients. Patients were 83.1±6.6 years old, and European system for cardiac operative risk evaluation score was 20.0%±11.4%. The BAV group was similar to the non-BAV group except for diabetes mellitus (4.8% vs 24.0%; P =0.05). The aortic annulus diameter in BAV patients was not significantly larger by multidetector computed tomography (24.7±3.0 vs 23.7±1.9 mm; P =0.07). The CoreValve was used more frequently in the BAV group (47.6% vs 16.3%; P =0.002). There was no significant difference in device success (100% vs 92.8%; P =0.37), risk of annulus rupture (0% vs 1.4%; P =1.00), or valve migration (0% vs 1.4%; P =1.00) in BAV patients compared with non-BAV patients. Postprocedural mean gradient (10.0±3.4 vs 9.7±4.1 mm Hg; P =0.58), aortic regurgitation ≥2 of 4 (19.0% vs 14.9%; P =0.54), 30-day mortality (4.8% vs 8.2%; P =1.00), and 30-day combined safety end point (14.3% vs 13.5%; P =1.00) were also similar in both groups. Conclusions— In selected BAV patients, transcatheter aortic valve implantation may be associated with low complication rate, efficacy, and acceptable outcomes similar to those in non-BAV patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3