Diagnostic Accuracy of Placental Growth Factor in Women With Suspected Preeclampsia

Author:

Chappell Lucy C.1,Duckworth Suzy1,Seed Paul T.1,Griffin Melanie1,Myers Jenny1,Mackillop Lucy1,Simpson Nigel1,Waugh Jason1,Anumba Dilly1,Kenny Louise C.1,Redman Christopher W.G.1,Shennan Andrew H.1

Affiliation:

1. From the Women’s Health Academic Centre, King’s College London, London, UK (L.C.C., S.D., P.T.S., M.G., A.H.S.); Maternal and Fetal Health Research Centre, University of Manchester, UK (J.M.); Oxford University Hospitals NHS Trust, Oxford, UK (L.M.); Section of Obstetrics & Gynaecology, University of Leeds, UK (N.S.); Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK (J.W.); Academic Unit of Reproductive and Developmental Medicine, University of Sheffield, UK (D.A.); The Irish...

Abstract

Background— Hypertensive disorders of pregnancy are a major contributor to death and disability for pregnant women and their infants. The diagnosis of preeclampsia by using blood pressure and proteinuria is of limited use because they are tertiary, downstream features of the disease. Placental growth factor (PlGF) is an angiogenic factor, a secondary marker of associated placental dysfunction in preeclampsia, with known low plasma concentrations in the disease. Methods and Results— In a prospective multicenter study, we studied the diagnostic accuracy of low plasma PlGF concentration (<5th centile for gestation, Alere Triage assay) in women presenting with suspected preeclampsia between 20 and 35 weeks’ gestation (and up to 41 weeks’ gestation as a secondary analysis). The outcome was delivery for confirmed preeclampsia within 14 days. Of 625 women, 346 (55%) developed confirmed preeclampsia. In 287 women enrolled before 35 weeks’ gestation, PlGF <5th centile had high sensitivity (0.96; 95% confidence interval, 0.89–0.99) and negative predictive value (0.98; 0.93–0.995) for preeclampsia within 14 days; specificity was lower (0.55; 0.48–0.61). Area under the receiver operating characteristic curve for low PlGF (0.87, standard error 0.03) for predicting preeclampsia within 14 days was greater than all other commonly used tests, singly or in combination (range, 0.58–0.76), in women presenting with suspected preeclampsia ( P <0.001 for all comparisons). Conclusions— In women presenting before 35 weeks’ gestation with suspected preeclampsia, low PlGF has high sensitivity and negative predictive value for preeclampsia within 14 days, is better than other currently used tests, and presents an innovative adjunct to management of such women.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 361 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3