Paclitaxel-Coated Balloon Catheter Versus Paclitaxel-Coated Stent for the Treatment of Coronary In-Stent Restenosis

Author:

Unverdorben Martin1,Vallbracht Christian1,Cremers Bodo1,Heuer Hubertus1,Hengstenberg Christian1,Maikowski Christian1,Werner Gerald S.1,Antoni Diethmar1,Kleber Franz X.1,Bocksch Wolfgang1,Leschke Matthias1,Ackermann Hanns1,Boxberger Michael1,Speck Ulrich1,Degenhardt Ralf1,Scheller Bruno1

Affiliation:

1. From the Institut für Klinische Forschung (M.U., R.D.) and Kardiologische Klinik (C.V.), Herz- und Kreislaufzentrum, Rotenburg an der Fulda, Klinik für Innere Medizin III, Universitätsklinikum des Saarlandes (B.C., B.S.), Homburg/Saar, Medizinische Klinik, Kardiologie, St. Johannes Hospital (H.H.), Dortmund, Klinik und Poliklinik für Innere Medizin II, Universitätsklinikum Regensburg (C.H.), Kerckhoff Klinik (C.M.), Bad Nauheim, Medizinische Klinik I, Klinikum Darmstadt (G.S.W.), I....

Abstract

Background— Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. Methods and Results— One hundred thirty-one patients with coronary in-stent restenosis were randomly assigned to treatment by a paclitaxel-coated balloon (3 μg/mm 2 ) or a paclitaxel-eluting stent. The main inclusion criteria encompassed diameter stenosis of ≥70% and ≤22 mm in length, with a vessel diameter of 2.5 to 3.5 mm. The primary end point was angiographic in-segment late lumen loss. Quantitative coronary angiography revealed no differences in baseline parameters. At 6 months follow-up, in-segment late lumen loss was 0.38±0.61 mm in the drug-eluting stent group versus 0.17±0.42 mm ( P =0.03) in the drug-coated balloon group, resulting in a binary restenosis rate of 12 of 59 (20%) versus 4 of 57 (7%; P =0.06). At 12 months, the rate of major adverse cardiac events were 22% and 9%, respectively ( P =0.08). This difference was primarily due to the need for target lesion revascularization in 4 patients (6%) in the coated-balloon group, compared with 10 patients (15%) in the stent group ( P =0.15). Conclusions— Treatment of coronary in-stent restenosis with the paclitaxel-coated balloon was at least as efficacious and as well tolerated as the paclitaxel-eluting stent. For the treatment of in-stent restenosis, inhibition of re-restenosis does not require a second stent implantation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 411 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3