Incidence and Clinical Relevance of Slow Ventricular Tachycardia in Implantable Cardioverter-Defibrillator Recipients

Author:

Sadoul Nicolas1,Mletzko Ralph1,Anselme Frédéric1,Bowes Robert1,Schöls Wolfgang1,Kouakam Claude1,Casteigneau Gaëlle1,Luise Raffaele1,Iscolo Nicolas1,Aliot Etienne1

Affiliation:

1. From CHU de Nancy Brabois, Vandoeuvre les Nancy, Nancy (N.S., E.A.), CHU Charles Nicolle, Rouen (F.A.), Hôpital Cardiologique, CHU de Lille, Lille (C.K.), CHU de Rangueil, Toulouse (G.C.), Ela Medical, and Le Plessis Robinson (N.I.), France; Herz-Kreislaufklinik Bevensen, Bad-Bevensen (R.M.), and Universitätskliniken Heidelberg, Heidelberg (W.S.), Germany; Northern General Hospital, Sheffield (R.B.), United Kingdom; and Ospedale Santo Spirito, Pescara (R.L.), Italy.

Abstract

Background— This study aims to assess the incidence and clinical relevance of slow ventricular tachycardia (VT) and the effectiveness and/or deleterious effects of antitachycardia pacing in slow VT in implantable cardioverter-defibrillator recipients. Methods and Results— This multicenter prospective randomized study included 374 patients (326 men) without prior history of slow VT (<148 bpm) implanted with a dual-chamber implantable cardioverter-defibrillator. Patients had a 3-zone detection configuration: a slow VT zone (101 to 148 bpm), a conventional VT zone (>148 bpm), and a ventricular fibrillation zone. Patients were randomized to a treatment group (n=183) with therapy activated in the slow VT zone or a monitoring group (n=191) with no therapy in the slow VT zone. During follow-up (11 months), 449 slow VTs occurred in 114 patients (30.5% slow VT incidence); 181 VTs (54 patients) occurred in the monitoring group; 3 were readmitted to the hospital; and lightheadedness and palpitations occurred in 4 and 250 (60 patients) in the treatment group treated by antitachycardia pacing (89.8% success rate) and shock delivery (n=2). There were 10 crossovers from the monitoring to treatment group and 3 crossovers from the treatment to monitoring group ( P =0.09). Quality of life scores were not different between groups. Conclusions— Slow VT incidence (<150 bpm) is high (30%) in implantable cardioverter-defibrillator recipients without prior history of slow VT, has limited clinical relevance, and is efficiently and safely terminated by antitachycardia pacing.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3