Reversal of Severe Heart Failure With a Continuous-Flow Left Ventricular Assist Device and Pharmacological Therapy

Author:

Birks Emma J.1,George Robert S.1,Hedger Mike1,Bahrami Toufan1,Wilton Penny1,Bowles Christopher T.1,Webb Carole1,Bougard Robert1,Amrani Mohammed1,Yacoub Magdi H.1,Dreyfus Gilles1,Khaghani Asghar1

Affiliation:

1. From the Royal Brompton and Harefield NHS Foundation Trust (E.J.B., R.S.G., M.H., T.B., P.W., C.T.B., C.W., R.B., M.A., G.D., A.K.) and Heart Science Centre, Imperial College (E.J.B., R.S.G., C.T.B., M.H.Y.), Harefield, Middlesex, UK, and University of Louisville, Louisville, KY (E.J.B.).

Abstract

Background— We have previously shown that a specific combination of drug therapy and left ventricular assist device unloading results in significant myocardial recovery, sufficient to allow pump removal, in two thirds of patients with dilated cardiomyopathy receiving a Heartmate I pulsatile device. However, this protocol has not been used with nonpulsatile devices. Methods and Results— We report the results of a prospective study of 20 patients who received a combination of angiotensin-converting enzymes, β-blockers, angiotensin II inhibitors, and aldosterone antagonists followed by the β 2 -agonist clenbuterol and were regularly tested (echocardiograms, exercise tests, catheterizations) with the pump at low speed. Before left ventricular assist device insertion, patient age was 35.2±12.6 years (16 male patients), patients were on 2.0±0.9 inotropes, 7 (35) had an intra-aortic balloon pump, 2 were hemofiltered, 2 were ventilated, 3 had a prior Levitronix device, and 1 had extracorporeal membrane oxygenation. Cardiac index was 1.39±0.43 L · min −1 · m −2 , pulmonary capillary wedge pressure was 31.5±5.7 mm Hg, and heart failure history was 3.4±3.5 years. One patient was lost to follow-up and died after 240 days of support. Of the remaining 19 patients, 12 (63.2) were explanted after 286±97 days. Eight had symptomatic heart failure for ≤6 months and 4 for >6 months (48 to 132 months). Before explantation, at low flow for 15 minutes, ejection fraction was 70±7, left ventricular end-diastolic diameter was 48.6±5.7 mm, left ventricular end-systolic diameter was 32.3±5.7 mm, mV̇ o 2 was 21.6±4 mL · kg −1 · min −1 , pulmonary capillary wedge pressure was 5.9±4.6 mm Hg, and cardiac index was 3.6±0.6 L · min −1 · m −2 . Estimated survival without heart failure recurrence was 83.3 at 1 and 3 years. After a 430.7±337.1-day follow-up, surviving explants had an ejection fraction of 58.1±13.8, left ventricular end-diastolic diameter of 59.0±9.3 mm, left ventricular end-systolic diameter of 42.0±10.7 mm, and mV̇ o 2 of 22.6±5.3 mL · kg −1 · min −1 . Conclusions— Reversal of end-stage heart failure secondary to nonischemic cardiomyopathy can be achieved in a substantial proportion of patients with nonpulsatile flow through the use of a combination of mechanical and pharmacological therapy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference18 articles.

1. Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation

2. Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device

3. Ventricular remodelling after prolonged ventricular unloading “heart rest” experience with the Heartmate left ventricular assist device;Frazier OH;J Heart Lung Transplant,1994

4. Left ventricular assist system as a bridge to myocardial recovery

5. Myocardial Recovery Using Ventricular Assist Devices