Total Systemic Vascular Compliance Measured as Incremental Volume-Pressure Ratio

Author:

SHOUKAS ARTIN A.1,SAGAWA KIICHI1

Affiliation:

1. Departments of Biomedical Engineering and Physiology, Schools of Engineering and Medicine, Case Western Reserve University, Cleveland, Ohio 44106

Abstract

We developed a method to measure the compliance, defined as ΔVΔP, of the total systemic vascular bed (C t ) without stopping systemic flow. In 10 open-chest dogs, venous return (and cardiac output) was maintained at a constant level by inserting a perfusion pump (with no reservoir) between the caval veins and the right atrium. About 5% of the estimated total blood volume was withdrawn from the dog within 45 seconds. Resultant changes in central venous pressure were measured 10, 30, 60, 120, and 180 seconds after the volume change. The bled volume was then reinfused to repeat similar venous pressure measurements for another 180 seconds. The measurements were repeated after slightly increasing the blood volume or sectioning the vagi. The mean value of C t measured 10 seconds after hemorrhage or reinfusion was 1.96 ± 0.10 ( SE ) ml/mm Hg/kg body weight before vagotomy. Paired t -tests indicated no significant difference between measurements of bleeding and reinfusion, measurements with different initial venous pressures or blood volume, or measurements before and after vagotomy. However, C t increased with time during the 2-minute period by about 25% of the initial 10-second value ( P <0.001) and remained constant thereafter.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference24 articles.

1. HEYMANS C AND NEIL E.: Reflexogenic areas of the cardiovascular system. Boston Little Brown & Co. 1968.

2. Reflex Control of the Systemic Venous Bed

3. Venous Return. In Handbook of Physiology, sec. 2, vol. 2, Circulation, edited by W.F. Hamilton and P. Dow. Washington;GUYTON A.C.;American Physiological Society,1963

4. Peripheral venous system. In Handbook of Physiology, sec. 2, vol. 2, Circulation, edited by W.F. Hamilton and P. Dow. Washington;ALEXANDER R.S.;American Physiological Society,1963

5. Veins and venous tone

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3