Comparison of Ambulatory and Home Blood Pressure Variability for Cardiovascular Prognosis and Biomarkers

Author:

Narita Keisuke1ORCID,Hoshide Satoshi1,Kario Kazuomi1ORCID

Affiliation:

1. Department of Medicine, Division of Cardiovascular Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.

Abstract

BACKGROUND: Although blood pressure variability (BPV) is reported to be associated with cardiovascular prognoses, it has not been established whether ambulatory BPV (ABPV; ie, short-term 24-hour BPV) or home BPV (HBPV; day-to-day BPV) is a superior clinical marker. METHODS: We analyzed the associations of ABPV and HBPV with cardiovascular prognoses and biomarkers in 1314 hypertensive outpatients who underwent both home and ambulatory BP measurements in the J-HOP study (Japan Morning-Surge Home Blood Pressure). BPV was evaluated by the SD, coefficient of variation, and average real variability of the patients’ 24-hour ambulatory and home systolic BP values. RESULTS: During the median 7.0-year follow-up, 109 cardiovascular events occurred. All SD, coefficient of variation, and average real variability values of the HBPV were significantly associated with cardiovascular risk even after adjusting by average 24-hour ambulatory systolic BP and each ABPV value: 1 SD of hazard ratio (95% CI) for the SD, 1.36 (1.14–1.63); coefficient of variation, 1.38 (1.16–1.66); and average real variability 1.29 (1.10–1.51) of HBPV. The ABPV parameters did not exhibit comparable relationships. The cardiovascular risk spline curves showed a trend toward increased risks with increasing HBPV parameters. There were no differences between ABPV and HBPV in the relationships with B-type natriuretic peptide and the urine albumin-creatine ratio. CONCLUSIONS: In this comparative analysis of ambulatory and home BP monitoring values in individuals with hypertension, ABPV was not significantly associated with cardiovascular prognosis adjusted by average BP level, and HBPV was suggested to have modest superiority in predicting cardiovascular prognosis compared with ABPV.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3