Quantification of regional myocardial blood flow using 13N-ammonia and reoriented dynamic positron emission tomographic imaging.

Author:

Kuhle W G1,Porenta G1,Huang S C1,Buxton D1,Gambhir S S1,Hansen H1,Phelps M E1,Schelbert H R1

Affiliation:

1. Department of Radiological Sciences, UCLA School of Medicine, University of California.

Abstract

BACKGROUND Regional myocardial blood flow has been quantified using transaxial positron emission tomographic (PET) imaging and tracer kinetic modeling. However, the use of transaxial images limits the accuracy of regional partial volume corrections and the localization of the quantified regional flow values. The purpose of the present study was to overcome both problems by calculating regional flows from reoriented short-axis PET images. METHODS AND RESULTS Twelve experiments were performed in four dogs. 13N-ammonia was injected intravenously while microspheres were administered into the left atrium during baseline, hyperemic, and low-flow conditions. Serial transaxial frames were acquired with a 15-plane PET scanner and reoriented into short-axis frames. The arterial input function and eight regional myocardial tissue activity curves were derived from the reoriented frames. The arterial input functions were corrected for ammonia metabolites, and the myocardial tissue curves were corrected for spillover of activity, partial volume effects, and heterogeneities in the image's spatial resolution introduced during reorientation. Corrections for regional partial volume were based on estimates of the regional myocardial activity thickness derived from reoriented diastolic images of the heart. The myocardial 13N-ammonia kinetics were described with a two-pool compartmental model. Values of regional myocardial blood flow by PET correlated linearly with those by microspheres (slope, 0.94; y intercept, 0.06 ml/min/g; r = 0.93) over a wide range of flows. CONCLUSIONS Regional myocardial blood flow can be measured accurately and noninvasively from serially acquired and reoriented short-axis 13N-ammonia images, thus overcoming limitations inherent to the use of transaxially acquired images and permitting a more complete evaluation of regional blood flows throughout the left ventricular myocardium.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3