Upper limit of vulnerability reliably predicts the defibrillation threshold in humans.

Author:

Hwang C1,Swerdlow C D1,Kass R M1,Gang E S1,Mandel W J1,Peter C T1,Chen P S1

Affiliation:

1. Division of Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA 90048.

Abstract

BACKGROUND The upper limit of vulnerability is the stimulus strength above which electrical stimulation cannot induce ventricular fibrillation even when the stimulus occurs during the vulnerable period of the cardiac cycle. The purpose of this study was to test the hypothesis that the upper limit of vulnerability can accurately predict the defibrillation threshold in patients undergoing implantable cardioverter-defibrillator (ICD) implantation using nonthoracotomy lead systems. METHODS AND RESULTS We studied 77 patients at the time of ICD implantation. Multiple endocardial-endocardial and endocardial-subcutaneous shock pathways were used. Two different protocols were used to test the upper limit of vulnerability. In protocol 1 (n = 17), the upper limit of vulnerability was tested with two shocks on the peak or the up-slope of the T wave of paced rhythm. The shocks were given randomly either at the peak and 20 milliseconds before the peak of T wave (n = 7) or at 20 and 40 milliseconds before the peak of T wave (n = 10). In protocol 2 (n = 60), the upper limit of vulnerability was tested with three shocks delivered at 0, 20, and 40 milliseconds before the peak of the T wave. The weakest shock that failed to induce ventricular fibrillation by a 5-J step-down or step-up method was defined as the upper limit of vulnerability. The defibrillation threshold was also determined by a 5-J step-down or step-up method. In protocol 1, the upper limit of vulnerability (9 +/- 6 J) was significantly lower than the defibrillation threshold (13 +/- 7 J) with a correlation coefficient of .87 and P < .001. In protocol 2, the upper limit of vulnerability (13 +/- 6 J) was not significantly different from the defibrillation threshold (13 +/- 6 J) with a correlation coefficient of .85 and P < .001. In 45 of the 60 patients, the upper limit of vulnerability was < or = 15 J; all had a defibrillation threshold of < or = 20 J. In 51 of the 60 patients, the upper limit of vulnerability was within 5 J of the defibrillation threshold. The upper limit of vulnerability overestimated the defibrillation threshold by > 10 J in 8 patients and underestimated the defibrillation threshold by > 10 J in only 1 patient. The overestimation and underestimation occurred only in patients with the upper limit of vulnerability > 15 J. CONCLUSIONS When tested with three shocks on and before the peak of the T wave, the upper limit of vulnerability accurately predicted the defibrillation threshold in patients undergoing ICD implantation using nonthoracotomy lead systems. This method required either one or no episodes of ventricular fibrillation in most patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 88 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Pacing and Defibrillation;Cardiac Pacing, Defibrillation and Resynchronization;2021-04-19

2. The Upper Limit of Vulnerability and Critical Points for Defibrillation;Cardiac Bioelectric Therapy;2021

3. The Virtual Electrode Hypothesis of Defibrillation;Cardiac Bioelectric Therapy;2021

4. Elimination of Purkinje Fibers by Electroporation Reduces Ventricular Fibrillation Vulnerability;Journal of the American Heart Association;2018-08-07

5. Defibrillation Threshold Testing: Current Status;Arrhythmia & Electrophysiology Review;2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3