Lead systems for internal ventricular fibrillation.

Author:

Deeb G M,Griffith B P,Thompson M E,Langer A,Heilman M S,Hardesty R L

Abstract

We examined the feasibility of using a standby automatic implantable defibrillator and established thresholds for internal defibrillation. The implantable defibrillator senses ventricular fibrillation and delivers an electrical impulse for defibrillation. Two lead systems for the device have been investigated. System I consists of two 12-cm2 silicone-covered titanium mesh patches attached to the atrial and diaphragmatic pericardial surfaces. System II has an identical diaphragmatic patch and a titanium spring catheter, with a 12-cm2 surface area of conductivity, placed transvenously in the right atrium. Both systems were implanted by thoracotomy in 12 dogs (mean weight 20 kg) and by a subxiphoid approach in 10 pigs (mean weight 20 kg). The defibrillation threshold (lowest energy required for 80% success) was determined periodically for 54 weeks in the dogs (615 trials) and at 6 weeks for the pigs (100 trials). In dogs, the mean defibrillation threshold with system I leads at 4 weeks was 10.5 J and did not change significantly over a 54-week period (p greater than 0.05). Similar results were obtained in the pig at 4 weeks. The defibrillation thresholds for both lead systems in dogs and pigs using a transpleural thoracotomy or a subxiphoid approach are satisfactory for an implantable defibrillator that produces 20-35 J.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference8 articles.

1. Standby Automatic Defibrillator

2. Ventricular defibrillation through a single intravascular catheter electrode system. (abstr) Cl;Mirowski M;Res,1971

3. Experimental ventricular defibrillation with an automatic and completely implanted system;Schuder JC;Trans Am Soc Artif Intern Organs,1970

4. The electrical dose for ventricular defibrillation with electrodes applied directly to the heart;Geddes LA;J Thorac Cardiovasc Surg,1974

5. Feasibility and Effectiveness of Low-Energy Catheter Defibrillation in Man

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Thoracotomy Elevates the Defibrillation Threshold and Modifies the Defibrillation Dose-Response Curve;Journal of Cardiovascular Electrophysiology;1997-01

2. A Conceptual Basis for Defibrillation Waveforms;Pacing and Clinical Electrophysiology;1996-08

3. The Defibrillation Threshold;Implantable Cardioverter Defibrillator Therapy: The Engineering-Clinical Interface;1996

4. Early Changes in Defibrillation Threshold Following Implantation of a Nonthoracotomy System in Dogs;Pacing and Clinical Electrophysiology;1994-11

5. Engineering considerations in the development of the automatic implantable cardioverter defibrillator☆;Progress in Cardiovascular Diseases;1993-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3