Abstract

A computer algorithm was developed and applied to measure brightness decay rates of myocardial contrast opacification observed with two-dimensional echocardiography (2DE). An agitated mixture of diatrizoate meglumine and saline (Renografin-saline) was injected into the left main coronary artery of 17 closed-chest dogs during the control state as well as after placement of an intracoronary plug to induce 85% stenosis in the left anterior descending coronary artery (LAD) in five dogs. In 12 dogs, injections were also performed distally to complete intracoronary balloon occlusion of the LAD. For each injection, up to 35 electrocardiographic-gated, end-diastolic 2DE frames were digitized into an image-processing computer that determined mean pixel brightness of each of 12 myocardial segments per 2DE short-axis cross-section. Time-activity curves for each segment were generated, and contrast decay half-life (t 1/2) was calculated. Mean t 1/2 for control-state injections was found to be 24.1 +/- 7.7 sec, as opposed to 293.8 +/- 164.5 sec after complete coronary occlusion (p less than .001). In the five dogs in which 85% LAD stenosis was induced, prolongation of contrast t 1/2 from 18.3 +/- 8.9 sec during control to 44.3 +/- 21.0 sec (p less than .001) after plug insertion occurred in myocardial segments subserved by the stenosed vessel. No significant change occurred in segments that were not supplied by the stenosed vessel (21.9 +/- 9.1 sec during control vs 24.9 +/- 11.6 after plug insertion into the LAD). A reproducibility study of injection-to-injection t 1/2 in the control state indicated a correlation coefficient of r = .84 and a standard error of the estimate (SEE) equal to 5.86 sec, while interobserver t 1/2 reproducibility was r = .91 and SEE = 5.21 sec. The t 1/2 measurement derived by computer analysis of myocardial contrast 2DE may serve as an index for characterization of regional myocardial blood flow and may be applicable to evaluate interventions that alter perfusion.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 53 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3