Abstract

The effector mechanism of hypoxic pulmonary vasoconstriction (HPV) involves K+ channel inhibition with subsequent membrane depolarization. It remains uncertain how hypoxia modulates K+ channel activity. The similar effects of hypoxia and mitochondrial electron transport chain (ETC) inhibitors on metabolism and vascular tone suggest a common mechanism of action. ETC inhibitors and hypoxia may alter cell redox status by causing an accumulation of electron donors from the Krebs cycle and by decreasing the production of activated O2 species (AOS) by the ETC. We hypothesized that this shift toward a more reduced redox state elicits vasoconstriction by inhibition of K+ channels. Pulmonary artery pressure and AOS, measured simultaneously using enhanced chemiluminescence, were studied in isolated perfused rat lungs during exposure to hypoxia, proximal ETC inhibitors (rotenone and antimycin A), and a distal ETC inhibitor (cyanide). Patch-clamp measurements of whole-cell K+ currents were made on freshly isolated rat pulmonary vascular smooth muscle cells during exposure to hypoxia and ETC inhibitors. Hypoxia, rotenone, and antimycin A decreased lung chemiluminescence (-62 +/- 12, -46 +/- 7, and -148 +/- 36 counts/0.1 s, respectively) and subsequently increased pulmonary artery pressure (+14 +/- 2, +13 +/- 3, and +21 +/- 3 mm Hg, respectively). These agents reversibly inhibited an outward, ATP-independent, K+ current in pulmonary vascular smooth muscle cells. Antimycin A and rotenone abolished subsequent HPV. In contrast, cyanide increased AOS and did not alter K+ currents or inhibit HPV. The initial effect of rotenone, antimycin A, and hypoxia was a change in redox status (evident as a decrease in production of AOS). This was associated with the reversible inhibition of an ATP-independent K+ channel and vasoconstriction. These findings are consistent with the existence of a redox-based O2 sensor in the pulmonary vasculature.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 350 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3