Abstract
Analysis of velocity acceleration proximal to a regurgitant valve has been proposed as a method to quantify the regurgitant flow rate (Qo). Previous work has assumed inviscid flow through an infinitesimal orifice, predicting hemispheric isovelocity shells, with calculated flow rate given by Qc = 2 pi rN2vN, where vN is user-selected velocity of interest and rN is the distance from that velocity to the orifice. To validate this approach more rigorously and investigate the impact of finite orifice size on the assumption of hemispheric symmetry, numerical and in vitro modeling was used. Finite-difference modeling demonstrated hemispheric shape for contours more than two orifice diameters from the orifice. More proximal than this (where the measured velocity vN exceeded 3% of the orifice velocity vo), flow was progressively underestimated, with a proportional error delta Q/Qo nearly identical to the ratio of contour velocity to orifice velocity, vN/vo. For the in vitro investigations, flow rates from 4.3 to 150 cm3/sec through 0.3 and 1.0 cm2 circular orifices were imaged with color Doppler with aliasing velocities from 19 to 36 cm/sec. Overall, the calculated flow (assuming hemispheric symmetry) correlated well with the true flow, Qc = 0.88Qo-7.82 (r = 0.945, SD = 12.2 cm3/sec, p less than 0.0001, n = 48), but progressively underestimated flow when the vN approached the orifice velocity vo. Applying a correction factor predicted by the numerical modeling, delta Q was improved from -13.81 +/- 13.01 cm3/sec (mean +/- SD) to +1.54 +/- 5.67 cm3/sec.(ABSTRACT TRUNCATED AT 250 WORDS)
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Cardiology and Cardiovascular Medicine,Physiology
Reference25 articles.
1. Utsunomiya T Ogawa T Doshi R Patel D Quan M Henry WL Gardin JM: Doppler color flow "proximal isovelocity surface area" method for estimating volume flow rate: Effect of orifice shape and machine factors. JAm Coll Cardiol 1991;17:1103-1111
2. Rodriguez L Vlahakes GJ Yoganathan AP Guerrero JL Weyman AE Levine RA: Quantification of regurgitant flow rate using the proximal flow convergence method: In vivo validation. (abstract) Circulation 1989;80(suppl II):II-570
3. Utsunomiya T Ogawa T Patel D Nguyen D Doshi R Gardin JM: Color flow Doppler "proximal isovelocity surface area" method for estimating volume flow: Independence from machine factors. (abstract) Circulation 1989;80(suppl II):II-571
4. Anderson DA Tannehill JC Pletcher RH: Computational Fluid Mechanics and Heat Transer. New York Hemisphere Publishing Corp 1984 pp 329-415
Cited by
143 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献