Relationship Between Distance and Change in Surface ECG Morphology During Pacemapping as a Guide to Ablation of Ventricular Arrhythmias

Author:

Li Anthony1,Davis Joseph Samuel1,Wierwille Jeremiah1,Herold Keith1,Morgan Dennis1,Behr Elijah1,Shorofsky Stephen1,Saba Magdi1

Affiliation:

1. From the Cardiovascular Sciences Research Centre, St George’s University of London, United Kingdom (A.L., E.B., M.S.); Fischell Department of Bioengineering, Clark School of Engineering, University of Maryland, College Park (J.S.D., J.W., K.H.); St Jude Medical, St Paul, MN (D.M.); and Division of Cardiology, Department of Medicine, University of Maryland Medical System, Baltimore (S.S.).

Abstract

Background— Pacemapping is used to localize the exit site of ventricular arrhythmia. Although the relationship between distance and change in QRS morphology is its basis, this relationship has not been systematically quantified. Methods and Results— Patients (n=68) undergoing ventricular arrhythmia ablation between March 2012 and July 2013 were recruited. Pacemapping was targeted to areas of voltage >0.5 mV. Linear mixed-effects models were constructed of distance against morphology difference measured by the root mean square error sum across all 12 ECG leads (E12). Forty of 68 (58%) patients had structural heart disease, and 21/40 (53%) patients were ischemic. Nine hundred thirty-five pacing points were collected, generating 6219 pacing site pair combinations (3087 [50%] ventricular bodies, 756 [12%] outflow tract, and 162 [3%] epicardial). In multivariable analysis, increase in E12 was predicted by increasing distance (0.07 per mm; 95% confidence interval 0.07–0.08; P <0.001). Compared with the left ventricle, E12 values were lower in the right ventricle ( P =0.037) and left ventricular outflow tract ( P <0.001) and higher in left ventricle–right ventricle pairs ( P =0.021) and left ventricular epicardium ( P =0.08). There was no difference in E12 in the right ventricular outflow tract compared with the right–left ventricular outflow tract ( P =0.75) pairs. Structural heart disease or inadvertent pacing in scar was not associated with changes in E12; however, the presence of latency and split potentials were associated with higher and lower E12 values, respectively ( P <0.001). Conclusions— A robust positive relationship exists between distance and QRS morphological change when restricting pacing points to areas of voltage >0.5 mV. Significant differences in the spatial resolution of pacemapping exist within the heart.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3