Pulsed-Field Ablation in Ventricular Myocardium Using a Focal Catheter

Author:

Yavin Hagai D.12ORCID,Higuchi Koji12ORCID,Sroubek Jakub12ORCID,Younis Arwa12,Zilberman Israel12,Anter Elad12ORCID

Affiliation:

1. Cardiac Electrophysiology Section, Department of Cardiovascular Medicine (H.D.Y., K.H., J.S., A.Y., I.Z., E.A.), Cleveland Clinic, Lerner Research Institute, Cleveland, OH.

2. Mark-Josephson and Andrew Wit Research Laboratory, Department of Cardiovascular & Metabolic Sciences (H.D.Y., K.H., J.S., A.Y., I.Z., E.A.), Cleveland Clinic, Lerner Research Institute, Cleveland, OH.

Abstract

Background: Pulsed-field ablation (PFA) is a rapid and nonthermal energy with higher selectivity to myocardial tissue in comparison to radiofrequency ablation. However, its effects on ventricular myocardium and titration of lesion dimensions have not been well studied. This study examined the effect of PFA on ventricular myocardium and the influence of application repetition on lesion dimensions. Methods: An 8-Fr lattice catheter with a compressible 9-mm nitinol tip was used with a PFA generator (Affera, Inc) applying a bipolar and biphasic waveform (±1.3–2.0 kV, 4 second per application). We examined the impact of single applications (1×) versus 4 repetitive applications (4×) interspaced by 10 seconds. The latter was performed to determine whether repetitions of a similar electrical field can increase lesion dimensions. Experiments were performed in an in vivo porcine model and a survival period of 24 hours (n=6) or 23±5.4 days (n=6) for evaluation of early and late histopathologic effects. Results: PFA in ventricular myocardium showed repetition dependency. Acute lesion depth and volume increased from 5.6±1.43 mm and 860±362 mm3 to 8.8±0.74 mm and 2383±548 mm3 for 1× and 4× applications, respectively ( P <0.001 for both comparisons). This effect was maintained in the chronic lesion phase with lesion depth and volume of 3.9±0.92 mm and 655±286 mm3 compared with 7.3±0.83 mm and 2170±488 mm3, respectively ( P <0.001 for both comparisons). Acute lesions showed well demarcated necrotic core without coagulation necrosis while chronic lesions showed tissue thinning with fibro-fatty replacement. Conclusions: PFA in ventricular myocardium exhibits repetition dependency as lesion dimension increases with consecutive applications of a similar electrical field.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3