Loss-of-Function SCN5A Mutations Associated With Sinus Node Dysfunction, Atrial Arrhythmias, and Poor Pacemaker Capture

Author:

Chiang David Y.1,Kim Jeffrey J.1,Valdes Santiago O.1,de la Uz Caridad1,Fan Yuxin1,Orcutt Jeffrey1,Domino Melissa1,Smith Melissa1,Wehrens Xander H.T.1,Miyake Christina Y.1

Affiliation:

1. From the Cardiovascular Research Institute (D.Y.C., X.H.T.W., C.Y.M.), Medical Scientist Training Program (D.Y.C.), John Welsh Cardiovascular Diagnostic Laboratory (Y.F.), and Department of Molecular Physiology and Biophysics (X.H.T.W., C.Y.M.), Baylor College of Medicine, Houston, TX; and Section of Pediatric Cardiology, Texas Children’s Hospital, Houston (J.J.K., S.O.V., C.d.l.U., J.O., M.D., M.S., C.Y.M.).

Abstract

Background— Cardiac device implantation can be complicated by inability to adequately place leads because of significant lead capture issues. This study sought to determine whether there are genetic bases that underlie poor lead capture. Methods and Results— Retrospective review of all patients with structurally normal hearts who underwent new device implantation at Texas Children’s Hospital between 2009 and 2014 was performed. Patients with inability to capture at 10 V or a final capture threshold ≥3 V at 0.4 ms during implant were analyzed. Among a total of 136 patients (median age, 13 years; range, 3 days to 46 years), 11 patients (8.1%) who underwent dual chamber device implantation had elevated thresholds in the atria (4), ventricle (3), or both chambers (4; atrial-lead threshold, 4.7±4.3 versus 0.7±0.3 V; ventricular-lead, 3.0±3.3 versus 0.7±0.3 V). All 11 patients presented with sinus node dysfunction and 10 had atrial arrhythmias. At implant, inability to find atrial capture was seen in 4 patients. Three demonstrated intermittent complete loss of ventricular capture after implantation: 1 has recurrent syncope, 2 eventually died. Genetic testing performed in 10 demonstrated 7 patients with 6 distinct SCN5A mutations, all predicted to be severe loss-of-function mutations by bioinformatic analyses. In the remaining patients, although putative pathogenic mutations were not found, multiple SCN5A polymorphisms were identified in 2 and a desmin mutation in 1. Conclusions— This study suggests that significant capture issues at implant may be because of loss-of-function SCN5A mutations, providing new insights into SCN5A function. Recognition of this association may be critical for planning device implantation strategies and patient follow-up.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3