Target Indices for Clinical Ablation in Atrial Fibrillation

Author:

Ullah Waqas1,Hunter Ross J.1,Baker Victoria1,Dhinoja Mehul B.1,Sporton Simon1,Earley Mark J.1,Schilling Richard J.1

Affiliation:

1. From the Cardiovascular Biomedical Research Unit, St Bartholomew’s Hospital, Barts Health NHS Trust, London, United Kingdom.

Abstract

Background— In animal studies of radiofrequency ablation, lesion sizes plateau as the maximum lesion size is reached for an ablation. Lesion parameters are not available in clinical ablations, but preclinical work suggests that these correlate with impedance drop and electrogram attenuation. Characterization of the relationships between catheter contact force, ablation duration, and these surrogate markers of lesion formation may allow us to define targets for effective ablation. Methods and Results— Fifteen patients undergoing first-time radiofrequency ablation for nonparoxysmal atrial fibrillation were studied. All were in atrial fibrillation at the time of the procedure. Ablations were performed with an irrigated-tip contact force–sensing catheter in temperature-controlled mode (temperature limited to 48°C, power to 30 W). Included were 285 left atrial static ablations, 247 with additional impedance data. The ablation force time integral (FTI) correlated with the attenuation of the electrogram with ablation (Spearman ρ, –0.14; P =0.02): the relationship plateauing from 500 g·s, a reduction in the electrogram amplitude of 20%. The FTI also correlated with the impedance drop during ablation (Spearman ρ, 0.79; P <0.0005): the relationship was logarithmic, the reduction in the impedance with an increasing FTI also plateauing from 500 g·s, an impedance drop of 7.5%. The ablation duration affected the impedance drop at an FTI if the duration was <10 s. Beyond this time point, the FTI achieved rather than the ablation duration or mean contact force applied determined the impedance drop. Conclusions— During nonparoxysmal atrial fibrillation ablation, an FTI of 500 g·s should be targeted with ablation duration of ≥10 s. Clinical Trials Registration— URL: http://clinicaltrials.gov/ . Unique Identifier: NCT01587404.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 59 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Role of impedance drop and lesion size index (LSI) to guide catheter ablation for atrial fibrillation;Pacing and Clinical Electrophysiology;2024-08-06

2. Advanced Electroanatomic Mapping: Current and Emerging Approaches;Current Treatment Options in Cardiovascular Medicine;2024-02-27

3. Very high‐power short‐duration catheter ablation for treatment of cardiac arrhythmias: Insights from the FAST and FURIOUS study series;Journal of Cardiovascular Electrophysiology;2023-10-19

4. Model-free and Vision-based Contact Force Control of Interventional Catheters;2023 3rd International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME);2023-07-19

5. Radiofrequency Ablation of the Diseased Human Left Ventricle;JACC: Clinical Electrophysiology;2023-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3