Geometric Vascular Remodeling After Balloon Angioplasty and β-Radiation Therapy

Author:

Sabaté Manel1,Serruys Patrick W.1,van der Giessen Willem J.1,Ligthart Jurgen M.R.1,Coen Veronique L.M.A.1,Kay I. Patrick1,Gijzel Anthonie L.1,Wardeh Alexander J.1,den Boer Ad1,Levendag Peter C.1

Affiliation:

1. From the Thoraxcenter, Heartcenter, Rotterdam, Dijkzigt Academisch Ziekenhuis Rotterdam, The Netherlands (M.S., P.W.S., W.J.v.d.G., J.M.R.L., I.P.K., A.L.G., A.J.W., A.d.B.); and the Daniel den Hoed Cancer Center, Rotterdam, The Netherlands (V.L.M.A.C., P.C.L.).

Abstract

Background —Endovascular radiation appears to inhibit intimal thickening after overstretching balloon injury in animal models. The effect of brachytherapy on vascular remodeling is unknown. The aim of the study was to determine the evolution of coronary vessel dimensions after intracoronary irradiation after successful balloon angioplasty in humans. Methods and Results —Twenty-one consecutive patients treated with balloon angioplasty and β-radiation according to the Beta Energy Restenosis Trial-1.5 were included in the study. Volumetric assessment of the irradiated segment and both edges was performed after brachytherapy and at 6-month follow-up. Intravascular ultrasound images were acquired by means of ECG-triggered pullback, and 3-D reconstruction was performed by automated edge detection, allowing the calculation of lumen, plaque, and external elastic membrane (EEM) volumes. In the irradiated segments, mean EEM and plaque volumes increased significantly (451±128 to 490.9±159 mm 3 and 201.2±59 to 241.7±74 mm 3 ; P =0.01 and P =0.001, respectively), whereas luminal volume remained unchanged (250.8±91 to 249.2±102 mm 3 ; P =NS). The edges demonstrated an increase in mean plaque volume (26.8±12 to 32.6±10 mm 3 , P =0.0001) and no net change in mean EEM volume (71.4±24 to 70.9±24 mm 3 , P =NS), resulting in a decrease in mean luminal volume (44.6±16 to 38.3±16 mm 3 , P =0.01). Conclusions —A different pattern of remodeling is observed in coronary segments treated with β-radiation after successful balloon angioplasty. In the irradiated segments, the adaptive increase of EEM volume appears to be the major contributor to the luminal volume at follow-up. Conversely, both edges showed an increase in plaque volume without a net change in EEM volume.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 112 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3