Variability of Magnetic Resonance Angiography and Computed Tomography Angiography in Grading Middle Cerebral Artery Stenosis

Author:

Wong K.S.1,Lam Wynnie W.M.1,Liang Eisen1,Huang Y.N.1,Chan Y.L.1,Kay Richard1

Affiliation:

1. From the Department of Medicine (K.S.W., R.K.) and the Department of Diagnostic Radiology and Organ Imaging (W.W.M.L., E.L., Y.L.C.), Prince of Wales Hospital, The Chinese University of Hong Kong, and the Department of Neurology (Y.N.H.), Peking Union Medical College Hospital, Beijing, China.

Abstract

Background and Purpose Magnetic resonance angiography and computed tomography angiography are new, noninvasive methods to provide images of the cerebral vasculature. The reliability of magnetic resonance angiography and computed tomography angiography when used to grade middle cerebral artery stenosis remains to be established. We sought to study the interobserver and intraobserver variabilities of magnetic resonance angiography and computed tomography angiography in grading middle cerebral artery stenosis. Methods A total of 50 middle cerebral arteries in 25 patients were studied with magnetic resonance angiography and computed tomography angiography. All patients had a history of ischemic stroke. The films were read independently by two observers on separate occasions. Films were shown again to the same observer 4 weeks after the first reading. The degree of middle cerebral artery stenosis was categorized into four grades: normal/mild, moderate, severe, and occluded. The interobserver and intraobserver variabilities were calculated by the κ statistic method. Results Interobserver variability for grading middle cerebral artery stenosis was good (κ=0.78) for magnetic resonance angiography and moderate (κ=0.51) for computed tomography angiography. There was perfect agreement between two observers in 86% of the vessels shown in magnetic resonance angiography and in 76% of the vessels shown in computed tomography angiography. Intraobserver variability for both imaging methods was good, with the κ value in the range of 0.70 to 0.76. Conclusions Our results suggest that according to our protocol, magnetic resonance angiography is more reliable than computed tomography angiography in grading middle cerebral artery stenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3