Visually Evoked Blood Flow Response Assessed by Simultaneous Two-Channel Transcranial Doppler Using Flow Velocity Averaging

Author:

Sturzenegger Matthias1,Newell David W.1,Aaslid Rune1

Affiliation:

1. the Department of Neurological Surgery, University of Washington (Seattle).

Abstract

Background and Purpose We assessed the influence of different visual stimuli and the reproducibility and habituation of evoked flow responses using simultaneous two-channel transcranial Doppler monitoring and flow velocity averaging. Methods We measured stimulus-related percentage changes in posterior cerebral, basilar, and middle cerebral artery blood flow velocities in 14 normal volunteers using stimulus-triggered velocity averaging. With a two-channel transcranial Doppler system, simultaneous measurements in two arteries (both posterior cerebral arteries and the basilar and middle cerebral artery) were taken using multiple-array light-emitting diodes applying flash stimuli. Both posterior cerebral arteries were monitored to assess reproducibility and habituation of the evoked response with repetitive measurements under unchanged conditions and to analyze the influence of different features of the visual stimulus. Results There was a distinctive increase in velocities resulting from visual stimuli in both posterior cerebral and the basilar arteries but not in the middle cerebral artery. The responses in both posterior cerebral arteries were larger than in the basilar artery ( P =.0001). Brightness ( P <.0001), as well as complexity ( P <.0001), of the visual stimulus had a significant influence on the response amplitude. There was a trend toward a greater right-sided activation. Amplitudes of the evoked response were very stable during repetitive testing (coefficient of variation of the difference was 0.6). There was a trend toward habituation with monotonous (flash) but not with complex visual stimuli. A “zero” stimulus produced no responses. Conclusions The use of flow velocity averaging and two-channel simultaneous recording increases the sensitivity of transcranial Doppler monitoring to detect and correlate selective flow changes in the posterior cerebral arteries resulting from cerebral activation produced by visual stimulation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3