Investigation of genesis of gallop sounds in dogs by quantitative phonocardiography and digital frequency analysis.

Author:

Aubert A E,Denys B G,Meno F,Reddy P S

Abstract

Several investigators have noted external gallop sounds to be of higher amplitude than their corresponding internal sounds (S3 and S4). In this study we hoped to determine if S3 and S4 are transmitted in the same manner as S1. In 11 closed-chest dogs, external (apical) and left ventricular pressures and sounds were recorded simultaneously with transducers with identical sensitivity and frequency responses. Volume and pressure overload and positive and negative inotropic drugs were used to generate gallop sounds. Recordings were made in the control state and after the various interventions. S3 and S4 were recorded in 17 experiments each. The amplitude of the external S1 was uniformly higher than that of internal S1 and internal gallop sounds were inconspicuous. With use of Fourier transforms, the gain function was determined by comparing internal to external S1. By inverse transform, the amplitude of the internal gallop sounds was predicted from external sounds. The internal sounds of significant amplitude were predicted in many instances, but the actual recordings showed no conspicuous sounds. The absence of internal gallop sounds of expected amplitude as calculated from the external gallop sounds and the gain function derived from the comparison of internal and external S1 make it very unlikely that external gallop sounds are derived from internal sounds.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference17 articles.

1. Aubert AE Denys BG DeGeest H Meno F Reddy PS: Quantitative phono study of intracardiac and external heart sounds. In Ostrow HG editor: Computers in cardiology. Seattle 1982 IEEE Computer Society pp 501-504

2. High-fidelity, infinite time constant calibrated pressure apexcardiogram and its correlation with high-fidelity left ventricular pressure.

3. Aubert AE Denys BG DeGeest H Kesteloot H: Computer processing of echocardiograms. In Ostrow HG editor: Computers in cardiology. Seattle 1982 IEEE Computer Society pp 459-462

4. Computer processing of echo-mechanocardiograms: Methods and results

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Additional Heart Sounds—Part 1 (Third and Fourth Heart Sounds);Indian Journal of Cardiovascular Disease in Women WINCARS;2020-06

2. Medical Acoustics;Springer Handbook of Acoustics;2014

3. Medical Acoustics;Springer Handbook of Acoustics;2007

4. Detection of the third heart sound using a tailored wavelet approach: Method verification;Medical & Biological Engineering & Computing;2005-04

5. In vivo comparison between two tip pressure transducer systems;International journal of clinical monitoring and computing;1995-05