Novel Index for Invasively Assessing the Coronary Microcirculation

Author:

Fearon William F.1,Balsam Leora B.1,Farouque H. M. Omar1,Robbins Robert C.1,Fitzgerald Peter J.1,Yock Paul G.1,Yeung Alan C.1

Affiliation:

1. From the Divisions of Cardiovascular Medicine (W.F.F., O.F., P.J.F., P.G.Y., A.C.Y.) and Cardiothoracic Surgery (L.B.B., R.C.R.), Stanford University Medical Center, Stanford, Calif.

Abstract

Background— A relatively simple, invasive method for quantitatively assessing the status of the coronary microcirculation independent of the epicardial artery is lacking. Methods and Results— By using a coronary pressure wire and modified software, it is possible to calculate the mean transit time of room-temperature saline injected down a coronary artery. The inverse of the hyperemic mean transit time has been shown to correlate with absolute flow. We hypothesize that distal coronary pressure divided by the inverse of the hyperemic mean transit time provides an index of microcirculatory resistance (IMR) that will correlate with true microcirculatory resistance (TMR), defined as the distal left anterior descending (LAD) pressure divided by hyperemic flow, measured with an external ultrasonic flow probe. A total of 61 measurements were made in 9 Yorkshire swine at baseline and after disruption of the coronary microcirculation, both with and without an epicardial LAD stenosis. The mean IMR (16.9±6.5 U to 25.9±14.4 U, P =0.002) and TMR (0.51±0.14 to 0.79±0.32 mm Hg · mL −1 · min −1 , P =0.0001), as well as the % change in IMR (147±66%) and TMR (159±105%, P =NS versus IMR % change), increased significantly and to a similar degree after disruption of the microcirculation. These changes were independent of the status of the epicardial artery. There was a significant correlation between mean IMR and TMR values, as well as between the % change in IMR and % change in TMR. Conclusion— Measuring IMR may provide a simple, quantitative, invasive assessment of the coronary microcirculation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 507 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3