Technique and Results of Linear Ablation at the Mitral Isthmus

Author:

Jaïs Pierre1,Hocini Mélèze1,Hsu Li-Fern1,Sanders Prashanthan1,Scavee Christophe1,Weerasooriya Rukshen1,Macle Laurent1,Raybaud Florence1,Garrigue Stéphane1,Shah Dipen C.1,Le Metayer Philippe1,Clémenty Jacques1,Haïssaguerre Michel1

Affiliation:

1. From Hôpital Haut-Lévèque, Université Bordeaux II Victor Segalen, Bordeaux-Pessac, France.

Abstract

Background— This prospective clinical study evaluates the feasibility and efficacy of combined linear mitral isthmus ablation and pulmonary vein (PV) isolation in patients with paroxysmal atrial fibrillation (AF). Methods and Results— One hundred consecutive patients (13 women; age 55±10 years) with drug-refractory, symptomatic paroxysmal AF underwent PV isolation and linear ablation of the cavotricuspid isthmus and the mitral isthmus (lateral mitral annulus to the left inferior PV). They were compared with 100 consecutive patients (14 women; age, 52±10 years) undergoing PV isolation and cavotricuspid ablation without mitral isthmus ablation. Bidirectional mitral isthmus block was confirmed by demonstrating (1) a parallel corridor of double potentials during coronary sinus (CS) pacing, (2) an activation detour by pacing either side of the line, and (3) differential pacing techniques. Isolation of all PVs and cavotricuspid isthmus ablation were performed successfully in all. Mitral isthmus block was achieved in 92 patients after 20±10 minutes of endocardial radiofrequency application and an additional 5±4 minutes of epicardial radiofrequency application from within the CS in 68, resulting in a conduction delay of 151±26 ms during CS pacing. Thirty-two patients with mitral isthmus ablation compared with 49 without had recurrent atrial arrhythmia ( P =0.02) requiring further ablation. At 1 year after the last procedure, 87 patients with mitral isthmus ablation and 69 without ( P =0.002) were arrhythmia free without antiarrhythmic drugs, mitral isthmus ablation being the only factor associated with long-term success (RR for AF recurrence, 0.2; CI, 0.1 to 0.4; P <0.001). Conclusions— Catheter ablation of the mitral isthmus results consistently in demonstrable conduction block and is associated with a high cure rate for paroxysmal AF.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 646 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3