Water Drinking Acutely Improves Orthostatic Tolerance in Healthy Subjects

Author:

Schroeder Christoph1,Bush Victoria E.1,Norcliffe Lucy J.1,Luft Friedrich C.1,Tank Jens1,Jordan Jens1,Hainsworth Roger1

Affiliation:

1. From Franz-Volhard Clinical Research Center, Medical Faculty of the Charité, Humboldt-University, Berlin, Germany (C.S., F.C.L., J.T., J.J.); and the Institute of Cardiovascular Research, University of Leeds, Leeds, United Kingdom (V.E.B., L.J.N., R.H.).

Abstract

Background— Orthostatic symptoms and syncope are common, even in apparently healthy subjects. In patients with severe autonomic dysfunction, water drinking elicits an acute pressor response and improves orthostatic hypotension. We tested the hypothesis that water drinking also improves orthostatic tolerance in healthy subjects. Methods and Results— In a randomized, controlled, crossover fashion, 13 healthy subjects (9 men, 4 women, 31±2 years) ingested 500 mL and 50 mL of mineral water 15 minutes before head-up tilt on two separate days. Finger blood pressure, brachial blood pressure, heart rate, thoracic impedance, and blood flow velocity in the brachial artery and the middle cerebral artery were measured. Orthostatic tolerance was determined as the time to presyncope during a combined protocol of 20 minutes of 60° head-up tilt alone, followed by additional increasing steps of lower body negative pressure (−20, −40, and −60 mm Hg for 10 minutes each or until presyncope). Drinking 500 mL of water improved orthostatic tolerance by 5±1 minute (range, −1 to +11 minutes, P <0.001). After drinking 500 mL of water, supine mean blood pressure increased slightly ( P <0.01) as the result of increased peripheral resistance ( P <0.01). It also blunted both the increase in heart rate and the decrease in stroke volume with head-up tilt. Cerebral blood flow regulation improved after water drinking. Conclusions— Water drinking elicits an acute hemodynamic response and changes in cerebrovascular regulation in healthy subjects. These effects are associated with a marked improvement in orthostatic tolerance.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3